Communication

error

Re-set required

Failure on LIN or CAN-Bus

Switch unit off for 10 seconds, then on.

Engineer required.

User

Engineer

11

Initialisation

error

Re-set required

Software failed when initialising 

hardware

Switch unit off for 10 seconds, then on

Wait. Generator will re-set every 

30 seconds. Engineer required.

User

Engineer

12

Current 

reading failure

Re-set required

Generator detects that current

does not reflect what controls

require

Switch unit off for 10 seconds, then on

Engineer required.

User

Engineer

13

Mains 

connection

error

Re-set required

Mains voltage is too high or

too low

Switch unit off for 10 seconds, then on.

Engineer required.

User

Engineer

14

Mains 

connection

error

Re-set required

Mains voltage is too high or

too low

Switch unit off for 10 seconds, then on.

Engineer required.

User

Engineer

15

Coil electrical

circuit

self-protected

Re-set required

Refer to Fault 04

Switch unit off for 10 seconds, then on.

Refer to Fault 04.

User

Engineer

Code

Error

Cause

Action

U / E

Summary of Contents for E3901i

Page 1: ...ICE CALL On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing In addition the Users Instructions should be handed to the User...

Page 2: ...ight bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been repor...

Page 3: ...on a cooking zone Pan bases should be constructed of a ferrous material and cannot be less than 120mm 12cm in diameter d Ensure that corresponding LED stops flashing and remains lit e Lift pan from zo...

Page 4: ...ts to spade terminal beside LED body flat side Remove two wires connected to LED Remove control knob Undo fixings that secure control to panel Remove associated LED if required Remove main access pane...

Page 5: ...the solution to rectify the condition SUPPLY PROTECTION DEVICE The appliance is fitted with a miniature circuit breaker MCB as additional protection against over current If unit fails to operate or sh...

Page 6: ...uneven distorted Faulty temperature sensor constantly recording ambient Switch unit off for 10 seconds then on Check pan has not boiled dry or is empty Check replace pan Engineer required User Enginee...

Page 7: ...that current does not reflect what controls require Switch unit off for 10 seconds then on Engineer required User Engineer 13 Mains connection error Re set required Mains voltage is too high or too lo...

Page 8: ...TWISTED THROUGH FERRITE BEAD FERRITE BEAD 16 ON 4 3 2 1 OFF ON 4 3 2 1 OFF L1 N E USE TWO TERMINALS FOR 0 5mm CABLE LABELED 9F 4 8 7 6 CHANNEL C 2 CHANNEL B 1 9 10 11 12 13 14 15 16 15 14 13 9 10 11 1...

Page 9: ...E E F1 S1 S2 Terminal Block MCB Generator Front Control Rear Control Rear LED Front LED Front Coil Rear Coil Cables Twisted Together Cables Twisted Together Around Ferrite B B C C 1 2 3 4 4 4 6 6 7 7...

Page 10: ...10...

Reviews: