Warranty does not cover :-

Correcting faults caused by incorrect installation of a product.

Where an engineer cannot gain access to a site or a product.

Repeat commission visits.

Replacement of any parts where damage has been caused by misuse.

Engineer waiting time will be chargeable.

Routine maintenance and cleaning.

Gas conversions i.e. Natural to Propane gas.

Descaling of water products and cleaning of water sensors where softeners/ conditioners are not fitted, 

or are fitted and not maintained.

Blocked drains

Independent steam generation systems.

Gas, water and electrical supply external to unit.

Light bulbs

Re-installing vacuum in kettle jackets.

Replacement of grill burner ceramics when damage has been clearly caused by misuse.

Where an engineer finds no fault with a product that has been reported faulty.

Re-setting or adjustment of thermostats when unit is operating to specification.

Cleaning and unblocking of fryer filter systems due to customer misuse.

Lubrication and adjustment of door catches.

Cleaning and Maintenance

• Cleaning of burner jets

• Poor combustion caused by lack of cleaning

• Lubrication of moving parts

• Lubrication of gas cocks

• Cleaning/adjustment of pilots

• Correction of gas pressure to appliance.

• Renewing of electric cable ends.

• Replacement of fuses

• Corrosion caused by use of chemical cleaners.

• Cleaning of all filters and airways

• Faults occurring as a result of airway obstruction.

• Use of the unit without filters.

2

Summary of Contents for E3901i

Page 1: ...ICE CALL On completion of the installation these instructions should be left with the Engineer in Charge for reference during servicing In addition the Users Instructions should be handed to the User...

Page 2: ...ight bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been repor...

Page 3: ...on a cooking zone Pan bases should be constructed of a ferrous material and cannot be less than 120mm 12cm in diameter d Ensure that corresponding LED stops flashing and remains lit e Lift pan from zo...

Page 4: ...ts to spade terminal beside LED body flat side Remove two wires connected to LED Remove control knob Undo fixings that secure control to panel Remove associated LED if required Remove main access pane...

Page 5: ...the solution to rectify the condition SUPPLY PROTECTION DEVICE The appliance is fitted with a miniature circuit breaker MCB as additional protection against over current If unit fails to operate or sh...

Page 6: ...uneven distorted Faulty temperature sensor constantly recording ambient Switch unit off for 10 seconds then on Check pan has not boiled dry or is empty Check replace pan Engineer required User Enginee...

Page 7: ...that current does not reflect what controls require Switch unit off for 10 seconds then on Engineer required User Engineer 13 Mains connection error Re set required Mains voltage is too high or too lo...

Page 8: ...TWISTED THROUGH FERRITE BEAD FERRITE BEAD 16 ON 4 3 2 1 OFF ON 4 3 2 1 OFF L1 N E USE TWO TERMINALS FOR 0 5mm CABLE LABELED 9F 4 8 7 6 CHANNEL C 2 CHANNEL B 1 9 10 11 12 13 14 15 16 15 14 13 9 10 11 1...

Page 9: ...E E F1 S1 S2 Terminal Block MCB Generator Front Control Rear Control Rear LED Front LED Front Coil Rear Coil Cables Twisted Together Cables Twisted Together Around Ferrite B B C C 1 2 3 4 4 4 6 6 7 7...

Page 10: ...10...

Reviews: