background image

11 

 

3.6 

THERMOCOUPLES and  FLAME FAILURE DEVICE 

(FFD)

 

3.6.1  Open Top Flame Failure Device Magnet Unit   

To remove and replace FFD magnet unit, the following  procedures must be followed. 

Isolate Gas 

supply.

 

Remove hob components as detailed in Section 3.2.2. Undo FFD thermocouple at rear of tap, undo FFD 

section at tap rear and withdraw.

 

Replace in reverse order.

 

3.6.2  Open Top Thermocouple

 

Remove hob as detailed in Section 3.2.2.

 

Remove  nut  that  secures  thermocouple  to  burner 

support  bracket  and  pull  thermocouple  through 

support bracket from underside.

 

Undo thermocouple connection at FFD section of gas 

tap  and carefully remove thermocouple.

 

Replace  in  reverse  order,  taking  care  to  position 

tip  correctly  in  relation  to    burner    ports.  

Thermocouple  tip  should  be  35mm  above 

support  bracket.  Ensure  thermocouple  does  not 

touch any part of burner when  fully re-assembled

. (Fig 11) 

3.6.3  Oven Flame Failure Device Magnet Unit

 

The oven FFD magnet unit is an integral thermostat part.  Remove  hob  components  as  detailed  in 

Section 3.2.2  to gain access to FFD. 

Isolate Gas supply.

 

Undo FFD thermocouple at thermostat rear. Undo rear  FFD section and withdraw. Replace in reverse 

order.

 

3.6.4  Oven Thermocouple

 

To  Remove Thermocouple

 

Remove facia panel as detailed in Section 3.2.1.  Remove hob fitments. See Sections 3.2.2 or 3.2.3 

as required.

 

Remove RH side panel. 

 

Undo  thermocouple  nut  at  thermostat  rear. 

 

Open over doors. remove shelves and base plate.   Undo nut 

that  secures  thermocouple  to  burner  bracket.  Remove 

sensor from burner bracket. Release thermocouple from clips 

in oven chamber.  Remove Thermocouple by feeding through 

slot in oven side panel.  Replace  in  reverse  order,  taking 

care  not  to  over  tighten,  ensure  side  wall  insulation  around 

thermocouple  access  slot  is  undamaged

 

then  ensuring 

position as indicated  in Figure 12.

 

 

3.7 

OVEN  IGNITERS and ELECTRODES

 

Igniter  is  piezo  spark  type  and  contains  no  batteries.  Unit comprises piezo spark igniter, lead and 

electrode  assembly.  Lead  and earth lead  are  push-fit  at  igniter  end.  Oven  igniter  electrode, 

Thermocouple, and burner ports should  be aligned as indicated in Figure 12. 

3.7.1  Oven Igniter

 

Remove  facia  panel as  detailed in Section  3.2.1.  Disconnect  igniter  earth  wire  and  .Pull back 

insulated sleeve and remove igniter lead connection from spark igniter.Undo nut that secures igniter 

in position. Remove Igniter. Replace in reverse order,  

3.7.2  Oven Electrode

 

Remove  oven  shelves  and  base  plate.  Remove tie wr aps and pull back insulated 

sleeve. 
Disconnect igniter lead from electrode.

 

Undo fixing that secures electrode to burner bracket.  Remove electrode and replace in reverse order 

ensuring position is as indicated in Figure 12.

 

   

Summary of Contents for Dominator Plus G3101

Page 1: ... during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE C...

Page 2: ...external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to customer misuse Lubrication and adju...

Page 3: ...etween rear and side of unit and any combustible wall Important If a unit is to be installed in suite formation with other matching appliances the instructions for all models must be consulted to determine the necessary clearances to any combustible rear wall or overlying surface Some models require greater clearances than others and the largest figure quoted in individual instructions will theref...

Page 4: ...ust be tested for gas tightness Procedure details can be found in IGE UP 1 The adjustable governor supplied must be fitted to natural gas appliances 1 5 ELECTRICAL SUPPLY Not applicable to this appliance 1 6 WATER SUPPLY Not applicable to this appliance 1 7 HEAT INPUTS NATURAL and PROPANE GAS kW net Btu hr gross 1 7 1 Total Inputs Model kW Btu hr I3B P I3 G3101 3101D Six Burner 38 9 146 000 30 8 G...

Page 5: ...at control manifold of 15mbar 6 inches w g For multi burner systems approximately half of the burners should be on when setting governor pressure 1 10 BURNER ADJUSTMENT NATURAL and PROPANE GAS 1 10 1 Burner Aeration Open top and oven burners are fitted with fixed injectors and set aeration apertures NO ADJUSTMENT is possible Solid top burners have fixed injectors and aeration shroud Shroud adjustm...

Page 6: ...ured in position The open top burner heads fit loosely upon aluminium bases of lift off construction 2 1 1 Fryplate Accessory If fryplate Figure 2 is supplied refer to user instructions for details Important note this should be operated on a low flame setting only 2 1 2 Flue Accessory A tall flue is available as an accessory that may be substituted for standard type supplied with unit Details of t...

Page 7: ...and select 210 C setting Allow oven to heat up and check temperature is 210 C 10 C If reading is outwith specified range the thermostat may be faulty In this case unit should be serviced see thermostat replacement and calibration procedure Turn gas supply to oven OFF and allow a sufficient cool down period before removing thermostat 2 5 3 Lighting Sequence Important Prior to operation ensure ALL p...

Page 8: ...MENTS AS DETAILED IN SECTION 1 After carrying out any servicing or exchange of gas carrying component ALWAYS CHECK FOR GAS TIGHTNESS 3 1 GAS CONVERSION CHECK LIST For All Appliances CHANGE INJECTORS CHANGE BY PASS SCREW AND SET LOW RATE Refer to Section 1 10 CHANGE DATA PLATE Ensure gas supply is disconnected before commencing Only reconnect gas supply after all conversion work has been completed ...

Page 9: ...er and ensure burner aeration adjustment see Section 1 10 Pilot injector a Remove pilot pipe from pilot assembly b Remove existing pilot injector from pilot pipe c Fit replacement injector over pipe d Refit pilot pipe to pilot assembly e Refit pilot assembly to burner f Leave solid top castings off to allow manometer to be fitted to burner test point 3 1 6 Resetting Low Rate Screw Figure 10 a Remo...

Page 10: ...nge Replace in reverse order 3 4 BURNERS 3 4 1 Open Top Remove hob components as Section 3 2 2 Undo burner pipe compression fitting Undo injector holder fixings Withdraw burner body Replace in reverse order 3 4 2 Oven Open oven doors and remove base panel Undo Gas connection Remove tie wrap pull back insulated sleeving and disconnect igniter lead at spark electrode end Undo FFD thermocouple at bur...

Page 11: ... as detailed in Section 3 2 1 Remove hob fitments See Sections 3 2 2 or 3 2 3 as required Remove RH side panel Undo thermocouple nut at thermostat rear Open over doors remove shelves and base plate Undo nut that secures thermocouple to burner bracket Remove sensor from burner bracket Release thermocouple from clips in oven chamber Remove Thermocouple by feeding through slot in oven side panel Repl...

Page 12: ... check gas tightness 3 9 2 Removal isolate from gas supply Remove control knobs and fascia panel as detailed in Section 3 2 1 Remove hob fitments as detailed in Sections 3 2 2 and 3 2 3 as appropriate Disconnect thermocouple connection at gas tap rear 3 10 GOVERNOR Natural Gas Models Only The governor supplied is maintenance free Check that blue dust cap is covering vent and in good condition as t...

Page 13: ...n 2 Check thermocouple is not damaged and is secured to gas valve FFD section to allow FFD to energise 3 Check FFD is energising and maintaining flame 4 If after carrying out the above burner is still not maintaining flame then re check from start SECTION 4 SPARES and ACCESSORIES When ordering spare parts always quote appliance type and serial number This information will be found on data badge at...

Reviews: