15
English
Service work should only be carried out by technically
competent and suitably qualifi ed personnel.
Spare Parts
To maintain optimum and safe performance, only use
genuine spare parts. Do not use re-conditioned or
unauthorised gas controls. Contact your retailer.
Installation
This appliance is designed for domestic cooking only.
Use for any other purpose could invalidate any warranty
or liability claim.
Before installation, ensure that cooker is suitable for your
gas type and supply voltage. See the the appliance data
badge.
Check the data badge to determine which gas the
cooker is set for.
Conversion
This appliance is supplied as: -
G 20 20millibar
CAT
II2H3+
A conversion kit for other gases is supplied with the
cooker.If the appliance is to be converted to another
gas we recommend that this is done before installation.
See the Conversion section of this instruction for more
details. After converting the appliance please attach the
Gas Conversion sticker over the appropriate area of the
data badge, this will identify the gas type the appliance
is now set for.
This appliance is designed for domestic cooking
only. Use for any other purpose could invalidate any
warranty or liability claim.
Safety Requirements/Regulations
You must be aware of the following safety
requirements & regulations
Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure) and the
adjustment of the appliance are compatible.
This appliance shall be installed in accordance with the
regulations in force and only in a well ventilated space.
Read the instructions before installing or using this
appliance.
In the UK
the regulations and standards are as follows:-
In your own interest and that of safety, it is law that all
gas appliances be installed by competent persons.
CORGI registered installers undertake to work to
safe and satisfactory standards. Failure to install the
appliance correctly could invalidate any warranty or
liability claims and lead to prosecution. The cooker must
be installed in accordance with
All relevant British Standards / Codes of Practice,
in particular BS 5440 Part 2 2000,
or Natural Gas - BS 6172 : 1990 and BS 6891 :
1998
For LP Gas - BS 5482-1:1994 (when the
installation is in a permanent dwelling), BS 5482-
2:1977, (when the installation is in a caravan or
other non permanent dwelling), or BS 5482-3:1999
, (when the installation is in a boat).
The Gas Safety (Installation and Use) regulations
1998.
The relevant Building / IEE regulations.
In the Republic of Ireland:-
The installation must be carried out by a Competent
Person and installed in accordance with the current
edition of I.S.813 “Domestic Gas Installations”, the
current Building Regulations and reference should be
made to the current ETCI rules for electrical installation.
Provision of Ventilation
This appliance is not connected to a combustion
products evacuation device. Particular attention shall be
given to the relevant requirements regarding ventilation.
In the UK
The room containing the cooker should have an air
supply in accordance with BS 5440 Part 2 : 2000. All
rooms require an openable window or equivalent, while
some rooms require a permanent vent in addition to the
openable window. The cooker should not be installed
in a bedsitting room with volume less than 20m
3
. If it is
installed in a room of volume less than 5m
3
an air vent
of effective area 100cm
2
is required; if it is installed in
a room of volume between 5m
3
and 10m
3
, an air vent
of effective area 50cm
2
is required; while if the volume
exceeds 11m
3
, no air vent is required.
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.
In the Republic of Ireland:-
Reference should be made to the current edition of IS
813 which makes clear the conditions that must be met
to demonstrate that suffi cient ventilation is available.
Location of Cooker
The cooker may be installed in a kitchen/kitchen diner
but NOT in a room containing a bath or shower.
NOTE:
An appliance for use on LPG shall not be installed in
a room or internal space below ground level. e.g. in
a basement.
Summary of Contents for 1000 DF
Page 2: ...2...
Page 3: ...3 English 4 Fran ais 30 FR GB IE...
Page 56: ...Falcon is a business name of AGA Consumer Products...