FTP3000 Series Programmable DC Power Supply Operation Manual
____________________________________________________________________________
- 36 -
Figure 3-25 RAMP Test Toggle Way
Table 3-8 RAMP Function Parameter Explanation
Parameter
Explanation
Way
CONT: Continuous way, PULS: Pluse way, TOGG: Toggle way
CV-1
RAMP test voltage 1, set range: 0 ~ Vmax
CV-2
RAMP test voltage 2, set range: 0 ~ Vmax
Slew-UP
Set voltage rise slew rate, range: 0.001V/s ~ 100V/s,
Slew-DN
Set voltage fall slew rate, range: 0.001V/s ~ 100V/s,
Width-1
Set RAMP pulse width 1, range: 0.5s ~ 60000s
Width-2
Set RAMP pulse width 2, range: 0.5s ~ 60000s
CC
Set RAMP test output current, range 0 ~ Imax
3.19 Sound
This parameter determines the sound of key pressing. There are two choices for this parameter setting:
●
Off, no sound if you press the key or rotate the rotary knob;
●
On, there is beep sound if you press the key or rotate the rotary knob.
-----------------------------------------------------------------------------------------------------------------------
There is always protection alarm sound, even if you turn off sound in parameter set.
-----------------------------------------------------------------------------------------------------------------------
3.20 Language
FTP3000 series display screen supports simplified Chinese, traditional Chinese, English.