For users
- 9 -
3. Technical specification
Model
IPHCR15
IPHCR20
IPHCR26
IPHCR33
IPHCR40
IPHCR45
IPHCR55
IPHCR70
IPHCR70T
IPHCR100T
Advised pool volume (m
3
)
15~30
20~40
25~45
30~55
35~65
40~75
50~95
65~120
65~120
90~160
Working air temp (℃)
-7~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
6.5
8.5
10.5
13.0
15.0
17.5
20.5
27.5
27.3
35.8
C.O.P
14.7~6.0
14.8~7.4
15.0~7.4
15.4~7.3
15.5~6.7
15.8~6.2
15.3~6.0
15.4~6.5
15.3~6.5
15.6~5.8
C.O.P at 50% speed
10.5
10.9
11.0
11.0
10.9
11.1
10.7
11.2
11.2
10.9
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
4.8
6.3
7.3
9.0
10.5
11.5
14.0
18.0
18.0
24.5
C.O.P
7.3~4.5
7.4~5.0
7.7~4.8
7.7~4.8
7.8~4.6
7.8~4.5
7.7~4.4
8.1~4.8
8.1~4.8
8.0~4.7
C.O.P at 50% speed
6.3
6.6
6.8
6.8
6.6
6.4
6.3
6.8
6.8
7.0
Performance Condition: Air 35°C, Water 28°C, Humidity 80%
Cooling capacity (kW)
3.0
4.0
4.6
5.6
6.8
7.8
10.0
12.2
12.2
16.5
Rated input power(kW) at
air 15°C
0.13~1.06
0.17~1.2
0.19~1.5
0.23~1.81
0.27~2.2
0.30~2.6
0.36~3.18
0.55~3.8
0.55~3.9
0.61~5.2
Rated input current(A) at
air 15°C
0.56~4.60
0.74~5.2
0.83~6.5
1.00~7.87
1.17~9.6
1.3~11.3
1.57~13.8
2.4~16.5
0.79~5.6
0.88~7.4
Power supply
230V/1 Ph/50Hz
400V/3 Ph/50Hz
Advised water flux (m³/h)
2~4
2~4
3~4
4~6
5~7
6.5~8.5
8~10
10~12
10~12
12~18
Sound pressure 1m dB(A)
37.8~47.2
38.8~48.2
38.6~49.9
42.1~50.7
41.3~55.0
43.1~53.8
40.9~54.2
43.5~54.9
43.5~54.9
42.6~54.7
Sound pressure 10m dB(A)
17.8~27.2
18.8~28.2
18.6~29.9
22.1~30.7
21.3~35.0
23.1~33.8
20.9~34.2
23.5~34.9
23.5~34.9
22.6~34.7
Water pipe in-out Spec
(mm)
50
Net Dimension LxWxH
(mm)
894×359
×
648
894×359
×
648
894×359
×
648
954×359
×
648
954×359
×
648
954×429
×
648
954×429
×
755
1084×429
×
948
1084×429
×
948
1154×539
×
948
Net Weight (kg)
42
45
49
50
52
63
68
90
93
120
1. The values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration
system running at least 15 hours a day.
2. Related parameters are subject to adjustment periodically for technical improvement without further
notice. For details please refer to nameplate.
Summary of Contents for Rapid RIC55
Page 2: ......
Page 20: ...For installers and professionals 17 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 21: ...For installers and professionals 18 APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 22: ...For installers and professionals 19 APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 78: ...F r Monteure und H ndler 18 Anhang 1 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 79: ...F r Monteure und H ndler 19 Anhang 2 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 80: ...F r Monteure und H ndler 20 Anhang 3 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 111: ......
Page 112: ...Version E12Ir32 1...