For installers and professionals
- 12 -
※ Above data is subject to modification without notice.
2.2.2. Heat pump installation.
The frame must be fixed by bolts (M10) to concrete foundation or brackets. The
concrete foundation must be solid; the bracket must be strong enough and anti-rust
treated;
The heat pump needs a water pump (Supplied by the user). The recommended pump
specification-flux: refer to Technical Parameter, Max. lift ≥10m
When the heat pump is running, there will be condensation water discharged from the
bottom, please pay attention to it. Please insert the drainage tube (accessory) into the
hole and clip it well, then connect a pipe to drain off the condensation water.
2.2.3. Wiring & protecting devices and cable specification
Connect to appropriate power supply, the voltage should comply with the rated voltage
of the products.
Well earth the heat pump.
Wiring must be connected by a professional technician according to the circuit diagram.
Set breaker or fuse according to the local code (leakage operating current ≤ 30mA).
The layout of power cable and signal cable should be orderly and not affecting each
other.
UNIT=MM
A
B
C
D
E
F
G
H
M
O
D
E
L
IPHCR15
334
590
318
359
894
250
74
648
IPHCR20
334
590
318
359
894
250
74
648
IPHCR26
334
590
318
359
894
290
74
648
IPHCR33
334
590
318
359
954
280
74
648
IPHCR40
334
590
318
359
954
340
74
648
IPHCR45
404
590
388
429
954
390
74
648
IPHCR55
404
590
388
429
954
460
74
755
IPHCR70
404
720
388
429
1084
620
74
948
IPHCR70T
404
720
388
429
1084
620
74
948
IPHCR100T
514
790
498
539
1154
650
74
948
Summary of Contents for Rapid RIC55
Page 2: ......
Page 20: ...For installers and professionals 17 APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 21: ...For installers and professionals 18 APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 22: ...For installers and professionals 19 APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL...
Page 78: ...F r Monteure und H ndler 18 Anhang 1 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 79: ...F r Monteure und H ndler 19 Anhang 2 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 80: ...F r Monteure und H ndler 20 Anhang 3 Schaltplan f r Heizpriorit tsfunktion Optional...
Page 111: ......
Page 112: ...Version E12Ir32 1...