Compressor protection:
•
Phase detector (machines running off a 3 phase current only): this mechanism shuts down the heat pump if
it detects the inversion of 2 phases or if one phase is missing
•
High T°C protection on the compressor return liner: this sensor shuts down the heat pump if the gas at the
compressor exhaust is too hot.
Technical Data
•
Titanium plate heat exchanger in a PVC box
•
Precise and accurate display of the water temperature. 3- An ecologically friendly heat transfer fluid, R410a.
•
High and low pressure safety mechanisms.
•
Automatic stop in the case of very low ambient temperatures. 6- Automatic defrosting.
•
International brand compressor. 8- Easy installation and operation.
•
Thermoformed ABS cabinet
•
Low flow detection by flow-switch controller
Technical spécifications
(1) Air at 15°C and 70 % RH, water at 26°C
(2) If the cable is longer, the cable cross section must be increased. For example, for a PH25L if the power cable is
shorter than 10 m, the cable cross section should be 3x2.5 mm², if the power cable is more than 10 m long, use
a cable with a cross section of 3 x 4 mm². Please note that the next cross section size up from 3 x 6 mm² is 3 x 10
mm².
(3) The remote installed control panel cable may not be longer than 50 m.
(4) Values shown are valid under the following conditions: Ambiant air temperature 15°C. Water temperature 25°C.
Pool covered with
an isothermal cover at night. Filtration system running at least 15 hours per day. Heating season: from May 1st to
September 15th.
CAUTION
1.
The models PH18L~PH80Ls operates within an ambient temperature range of 0 to +43 , and models
PHC120Ls and PHC150Ls operate within an ambient temperature range of -7 to +43 .
Their efficiency
cannot be guaranteed outside this range. Performance data and operating parameters can vary with
changes in climatic conditions.
2.
The technical specifications are subject to modification without prior notification with the aim of improving
our products. Please see the identity plated affixed to the heat pump for more information.
Model
PHC18L
PHC25L
PHC35L
PHC50L
PHC60L
PHC60LS
PHC80LS
PHC120LS
PHC150LS
Certified heating power output at 15° C (kW) (1)
4,80
6,60
9,90
11,40
16,00
16.00
22,20
29,40
40,10
Certified C.O.P. at 15° C (1) (Coef. Of performance)
4,52
4,64
4,78
4,68
4.51
4.60
5,16
5.04
5.05
Certified power consumption (kW) (1)
1,10
1,40
2,10
2,40
3.50
3.50
4,30
5,80
7,90
Heating power at 26° C (kW)
7,50
10,00
13,50
17,50
25.00
25.00
33,00
45,00
60,00
Cooling power (air at 35°C / water at 28°C) (kW)
4,3
6,0
8,0
10,0
15,0
15,0
20,0
27,0
36,0
EER (Energy Efficiency Ratio in cooling mode)
4,0
4,0
4,0
3,8
4,2
4,2
4,0
4,5
4,5
Power supply (V)
230 Volts / 1 ph / 50 Hertz
400 V / 3 ph / 50 Hz
Nominal current (A)
5,00
6,50
9,50
11,40
16,00
5.50
9,20
11,40
15,20
Power cable cross section (mm²) for cable ≤ 10 m (2)
3 x 2,5
3 x 2,5
3 x 2,5
3 x 4,0
3 x 6,0
5 x 2,5
5 x 4,0
5 x 4,0
5 x 6,0
Remote control panel cable cross section (mm2) (3)
3 x 0.5
Dispositif résiduel différentiel (mA)
30
Short circuit and overload breaker with D-curve
Nominal breaking current In (A)
8
10
14
(16 if non
ajustable)
16
20
8
14
(16 if non
ajustable)
16
20
Compressor type
Rotatif - R 410A
Scroll - R 410A
R 410 A quantity (in kg)
0.90
1.15
1.70
1.90
2.50
2.50
3.20
5.80
6.30
Certified sound power in dB(A)
61,1
61,8
65,7
68,4
69,5
69,4
69,5
72,9
79,6
Recommended flow rate (m3/h)
3 à 4
4 à 6
5 à 7
6,5 à 8,5
7 à 9
7 à 9
10 à 12
15 à 20
20 à 25
Water pipes external diameter (mm)
50
63
Net weight/ gross weight (Kg)
42/49
55/63
70/80
75/84
105/117
105/117
123/138
215/236
225/246
maximum recommended pool volume, m3 (4)
35
50
70
90
110
110
150
210
280