![background image](http://html1.mh-extra.com/html/fagor/dds/dds_quick-reference_3242451055.webp)
Fagor
C
ompact Drives and Motors
Q
uick
R
eference. Ref.1910
CQR-55/56
VECON-X BOARDS
ACD/SCD - ... - L MODELS
Drive software versions older than 09.05 are NOT compatible with
ACD/SCD X.X-...-
L
models (input line voltage: 3-ph. 200/240 V AC).
TRANSFER OF · *.MOT · FILES · MOTOR TABLE
Transferring any (*.mot) motor file (AKA motor table) whose version
is higher than 02.01 requires having a software version 08.09 or
higher installed at the drive.
SOFTWARE
INTERFACE
VECON BOARD
Up to 06.01
SERCOS
VECON
06.01 up to 06.17 SERCOS
VECON-2, VECON-3
06.18 up to 06.25 SERCOS
VECON-2, VECON-3
06.26 and later
SERCOS
VECON-2, VECON-3, VECON-4
07.0x
CAN
VECON-2, VECON-3
08.01 to 08.04
CAN
VECON-2, VECON-3
08.05 to 08.09
SERCOS/CAN
VECON-2, VECON-3,
VECON-4 (vers.00A)
08.10 and later
SERCOS/CAN VECON-2, VECON-3,
VECON-4 (vers.00A and later)
Note.
Drive software versions older than 08.09 are NOT compatible
with motor table version 02.02 or higher.
SOFTWARE VERSION
MOTOR TABLE VERSION
Up to 08.08 included
02.01
08.09
02.02
08.10
02.03
08.11
02.03
08.12
02.05
08.13
02.06
08.14
02.07
08.16
02.08
08.17 | 08.18 | 08.19
02.09
08.20
02.10
09.01
02.11
09.03 | 09.04 | 09.05
02.12