INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM

1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by qualified and authorized 
technicians in compliance with the existing regulations (www.fadini.net/supporto/download).
2) This automatic system is intended to be exclusively used for the applications described in this manual, including all of the 
safety and command accessories, at least as required.
3) Any application not indicated in this manual may cause malfunctioning or damages to people and properties.
4) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system.
5) Make sure the site is free from utilities that may interfere with it.
6) Make sure that electromagnetic sources are at a suitable distance from the accessories, especially from the loop detectors. 
The magnetic fields of other sources might affect the detections of the safety loops as well as those of the other command 
and safety devices of the system.
7) Make sure the power supply to the electric motor is 230 V (50 Hz).

8) 

It is recommended either of the following power supply cables:

- 10 meters electric cable 4x1 mm² for motor pump power supply;
- 10 meters electric cable 3x0,5 mm² for limit switches.
The section of the ground cable is to be chosen in compliance with the requirements of the installation site.

9) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
10) The installer shall provide the final user with information related to all of the operating commands and functions of the 
system, including that concerning lowering of the post in case of an emergency (manual release operation).
11) The installer shall inform the final user of the dangers coming from the presence of persons, especially children, in the 
proximity of the bollard. 
12) The manufacturer reserves the right to change this manual without previous notice.

As far as configuration and execution of the system are concerned, these are to comply with the laws in the country of 
installation.

Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not 
indicated in this manual, furthermore it is not answerable for malfunctioning caused by the use of materials 
or accessories not approved by the company itself.
It is to be noted that the product respects the impact and breakout resistance values as indicated provided 
that the installation of the same is carried out in observance of the specifications included in this manual of 
instructions. Various factors are to be carefully taken into consideration such as compaction index, soil 
permeability coefficient, concrete type, which may affect the indicated values even significantly.

PRODUCT SPECIFICATIONS

Heavy duty, fully retractable, automatic bollard made up of an incorporated oil-hydraulic motor pump unit and an 
oil-hydraulic actuator inside the moving cylinder. Suitable for applications in private and commercial areas, and for industrial 
installations. IP67. The height of the rising cylinder (from ground level) can be 500/600/800 mm. The rising cylinder is made 
of S235JRH steel, thickness 4 mm and Ø 200 mm, cataphoresis treated and powder coated. Rising cylinder also available in 
AISI 304 brushed stainless steel. Rubber ring on rising cylinder head. Cataphoresis treated aluminium cover with slip proof 
finish on treadable top. Rising cylinder fitted with high intensity, microprismatic, retroreflecting approved sticker (h 80 mm), 
available with signal LEDs (N.8) with flashing light fitted all around the top. Hot dip galvanized steel casing for ground 
foundation, fitted with a cover allowing access to the hydraulic release for manual lowering of the bollard by a special 
spanner in an emergency. Impact resistance 30.000 J, breakout resistance 160.000 J, static load max 1.600 kg in standing 
position, max 20.000 kg in lowered position. Working temperature -40°C +80°C. Supply voltage 230 Vac ± 10%, 50 Hz. 
Absorbed power 330 W. Rising time ~ 5,1 s [rising cylinder H 500 mm], ~ 5,9 s [rising cylinder H 600 mm] ~ 7,7 s [rising cylinder 
H 800 mm]. Frequency of use 2.000 cycles/day. Hydraulic device to lock the bollard in the standing position, on request a 
solenoid valve can be fitted for the spontaneous descent of the bollard in case of a power failure.

Summary of Contents for VIGILO 2250

Page 1: ...EN 13241 EN 12453 EN 12445 VIGILO VIGILO 2250 2263 2280 2250 2263 2280 GB Instructions manual pages 1 16 the gate opener FULLY RETRACTABLE OIL HYDRAULIC BOLLARDS POST DIAMETER 100 mm...

Page 2: ...e mains by switching off the master switch If removing the actuator do not cut the electric wires but disconnect them from the terminal box by loosening the screws inside the junction box INSTALLATION...

Page 3: ...e of rust treated steel 200 mm diameter bollards are also available in stainless steel AISI 304 version The product s hallmark is its ease of installation once the housing has been secured the operato...

Page 4: ...ractable post with hoisting connection English fully retractable oil hydraulic bollard PRELIMINARY OPENING OF ALL FUNCTIONAL COMPONENTS Start by removing the cover plate to reveal the operator and sep...

Page 5: ...lectricity cables with a 1 5 mm section for a maximum distance of 50 metres For distances of over 50 metres use electric cables with sections suited to the installation 2x1 mm cable RG58 1 MIRI 4 Led...

Page 6: ...draulic bollard Pic 4 Pic 5 850 stroke 500 mm 960 stroke 600 mm 1 140 stroke 800 mm ARRANGING THE HOUSING Check soil natural permeability 50 liters of water must be able to soak away in not longer tha...

Page 7: ...e housing The subsequent phase of this operation consists in threading the motor limit switch solenoid valve and LED power supply electric wires through the piping and simultaneously starting to delic...

Page 8: ...ng and controlling operations The magnetic loop detector is a safety device operating all the time to detect any transiting vehicle the bollard is prevented from rising should a vehicle cross the loop...

Page 9: ...ts on the Elpro S40 board are to be bridged and the respective connections with the Elpro S40 programmer and having completed thorough risk analysis the first operation manoeuvres can be performed If...

Page 10: ...ilizer to terminals 22 and 23 in the Elpro S40 control box Pic 12 VIGILO with solenoid valve VIGILO with solenoid valve VIGILO with solenoid valve SOLENOID VALVE STABILIZER GROUND LEVEL CLOSURE COVER...

Page 11: ...Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including inst...

Page 12: ...English VIGILO VIGILO fully retractable oil hydraulic bollard 12...

Page 13: ...the electronic board controlling the bollard s e g flooded relay contacts oxidized terminal clamps etc Check the correct functioning and positioning of the limit switches Check the release system for...

Page 14: ...ned these are to comply with the laws in the country of installation Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not indicated in this manual fur...

Page 15: ...263 Frequency of use intensive Service cycle rise 5 9 s dwell 30 s lower 5 2 s dwell 30 s Complete cycle time 71 s Complete cycles rise dwell lower dwell No 51 hour Annual cycles with 8 hours of use p...

Page 16: ...275 G 850 960 1 140 H 1 350 1 560 1 940 Pic 15 30 000 J 160 000 J Various factors such as the compaction index soil permeability coefficient and kind of concrete may reduce the values indicated in th...