background image

Pic. 3

INSTALLATION DISTANCES FOR THE GATE TO OPEN INWARDS

Gate stop in 

closed position

Gate stop in 

open position

90° 

5

Stroke C (mm)   

   A 

   B 

D (max)   E 

L

280 

 

 

140 

130 

70 

  80 

620 

 

280 braking 

 

110 

130 

70 

  80 

615

400 

 

 

180 

200 

130 

110 

820

400 braking 

 

170 

180 

120 

110 

810

500 

 

 

240 

240 

170 

140 

965

500* braking 

 

220 

220 

150 

140 

965

600* braking 

 

150 

380 

140 

1.220

700* braking 

 

180 

450 

160 

1.380

800* braking 

 

200 

520 

180 

1.550

900* braking 

 

230 

580 

200 

1.710

1.000* braking   

240 

670 

220 

1.890

* The installation dimensions for the special strokes have been studied  to take full advantage of the braking action in 
opening and closing cycles. In case any of the special strokes be required in non braking version, our technical team 
should be contacted and complete details of the gates provided for evaluation.

Installation distances in (mm) for opening 

90°

B

D  

Misalignment of the 

fixing plates: 18-20 mm

MAX. GATE WIDTH PER LEAF (m)

The gate structure, design (solid, in-filled), 
height and strong wind pressure may affect 
and  decrease  the  indicated  values.  Make 
always sure the gate structure is adequate to 
automation.

100

1

2

3

4

2,8

200

300

400

500

600

700

corsa 280 mm

corsa 400 mm

Stroke 280 mm

Stroke 400 mm

M

A

X

. G

A

T

E

 W

E

IG

H

T

 P

E

R

 L

E

A

F

 (

k

g)

MEC 800 Special

External oil-hydraulic operator for swinging gates

of large dimensions. With separate motor-pump.

E

n

g

li

sh

Summary of Contents for MEC 800 Special

Page 1: ...EN 13241 EN 12453 EN 12445 MEC 800 Special External oil hydraulic operator for swinging gates of large dimensions With separate motor pump GB Instructions manual pages 1 12 the gate opener...

Page 2: ...the gate warning about the presence of an automated installation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including...

Page 3: ...control box type Elpro be tted externally in a sheltered place Operations can be selected to be either fully automatic or semiautomatic closing by pulse depending on the user s requirements The syste...

Page 4: ...0 Junction pit 11 Gate stop in open position 12 Fit 55 photocell transmitter on post mount 13 Fit 55 photocell receiver on post mount 14 Gate electric lock 15 Fit 55 photocell transmitter 16 Gate stop...

Page 5: ...of the braking action in opening and closing cycles In case any of the special strokes be required in non braking version our technical team should be contacted and complete details of the gates prov...

Page 6: ...istances as indicated in Pic 3 Measurement established by distance B Pic 3 Measurement established by distance E Pic 3 M8 expanding bolts to suit material of gate post or wall Strengthening plate not...

Page 7: ...on block while the exible hoses are to provide connection between the junction block and the actuator sharp bends are to be avoided as well as rigidity the hoses are still to stay exible with the gate...

Page 8: ...e each adjustment screw controls the pressure to the nearest hydraulic joint it is fundamental to make sure that the joint corresponding to the red screw be the one allowing for the gate to close whil...

Page 9: ...having the hydraulic locking device it is possible to override the system for manual operations by the release knob positioned between the high and low pressure valves and give 1 2 turns maximum With...

Page 10: ...NG THE ACTUATOR COVER MEC 800 Special 10 External oil hydraulic operator for swinging gates of large dimensions With separate motor pump English Pic 13 MEC 700 80 VENTIL HYDRAULIC UNIT Blue common Pha...

Page 11: ...llard Road barrier Operator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extr...

Page 12: ...Oil type Oil Fadini Item 708L Working temperature 25 C 80 C Oil reservoir capacity 4 5 l Static motor pump weight 16 kg Protection standard IP 65 inside the enclosure 40 C with speci c optional acces...

Reviews: