page 15
XE
Dip-Switches and LED signals of the various functions
adjusts the
opening distance of the gate, for the
pedestrian opening contact up to 30 s
3
ON
:
Closes automatically
OFF
:
Semi-automatic
DIP-SWITCH-A N°3:
Description
This function allows automatic re-closure of the gate 3 seconds after passage between
the pair of photocells
11
ON
:
Automatic re-closure after passage
between the pair of photocell after 3 seconds
OFF
:
No automatic re-closure
DIP-SWITCH-A N°11:
Opens the gate for pedestrian passage using the OPEN
command,
:
- 1 pulse = opens the gate as pre-set by the trimmer;
- 2 pulses = full opening of the gate;
(It is advised to use the pedestrian opening mode with
Dip-A No.3 = ON for automatic re-closing).
The function
"
Pedestrian Opening
" is not in service during
the first operation cycle, after a power failure.
6
ON
:
Pedestrian opening
OFF
:
Pedestrian opening excluded
DIP-SWITCH-A N°6:
4
ON
:
Activates the DSA safety control
OFF
:
Deactivates DSA safety control
DIP-SWITCH-B N°4:
The open/close operations are achieved by "holding on a command switched" (the relay is
not self-retaining) and consequently the user must be actively present during all automation
movements until the push-button or the key-switch is released.
2
ON
:
Activates the deadman function
OFF
:
Deactivates the deadman function
DIP-SWITCH-B N°2:
NO
External clock
3
DIP-SWITCH-A N°3:
3 4
16
15
FUNCTIONS FOR SLIDING GATE OPENING - Dip Switch B n°1=ON
meccanica
FADINI
X
UNIVERSAL ELECTRONIC CONTROL BOX
230V 50/60Hz SINGLE-PHASE
GB
with one impulse from the open command the gate opens and stops in
Pause mode for the time set on the
. When this time expires the gate
automatically closes
with one impulse from the open command the gate opens and
stays open, motor stopped. To close the gate you must give the close impulse.
For the
control ( evice for afety uto-test) it is necessary to
connect
to this specifically
dedicated output and select
the ELPRO X and
ELPRO XE will check that all the connected photocell devices are
cleared from obstacles and properly working before starting any
gate movements, otherwise the gate does not start.
for
photocell TX
assigned to the
Connection: connect the Clock NO contact in
parallel with OPEN terminal No. 4 and COMMON
No. 3, activating automatic re-closure with
Dip-Switch No. 3=ON.
Operation: program the opening time on the
clock. When this present time comes up the gate
will open and remain open (the flashing light turns
off) and will not accept any other command (not
even radio commands) until the time set on the
clock expires. When this time expires the gate
automatically closes after the pause time.
During the dwell time, with the gate in open
position and system set to time “clock”
operating mode, the indicator light will give out
2 consecutive flashes followed by a long pause.
ON
:
Closes automatically
: adjusts pause time for
Automatic mode from 1s up to 220 s
-
-
XE