ELECTRONIC CONTROLLER FOR DARDO 424 GATE OPERATOR
ON DOUBLE SWINGING GATES
Elpro 42
GB
13
24 Vac output
max. load 500 mA:
n° 1 radio receiver
n° 2 pairs of photocells
n° 1 led Chis 37/Chis-E 37 or DGT 61 PCB
Input for
pedestrian
opening
12 Vdc output
for the electric lock
+
-
ON:
pre- ashing before opening
OFF:
no pre- ashing
ON:
DSA control enabled on photocells.
It is necessarily required that the photocells
projectors be power supplied to 13-14 terminals
OFF:
no DSA control on the photocells
ON:
asher disabled in dwell time on automatic
mode of operation (
Dip 3 = ON
)
OFF:
it ashes in dwell time
on automatic mode of operation (
Dip 3 = ON
)
DIP-SWITCHES N° 4 and 8:
DIP-SWITCH N° 10:
4
10
8
24 V - max 500 mA output:
24 Vdc asher:
24 Vac/dc output
for DSA control
Input for pedestrian
opening
(M1 motor only)
Electric lock output
12 Vdc
24 Vdc output for the asher
Photocells projectors
L15 green ON
= safety edge in opening.
It goes OFF whenever the safety edge is
activated
L16 green ON
= safety edge in closing.
It goes OFF whenever the safety edge is
activated
M1
In series if
NC mechanical type
In series if
NC mechanical type
In parallel if
8,2 kΩ resistive type
In parallel if
8,2 kΩ resistive type
8,2 kΩ
Input for
safety edge
in closing
Input for
safety edge
in opening
!
For a proper latching of the
electric lock, adjust slowdown
speed accordingly .
ON:
stroke reversing pulse enabled for 2 s
in opening
OFF:
stroke reversing pulse disabled
DIP-SWITCH N° 7:
7
Accessory
Electrical connections
Dip-switches and LED indication
of the various functions
9 10
11 12
13
15
16 17
17 18
19 20
16 17
17
15
17
14
24 V output to power supply the projectors of the
photocells (power supplied in parallel) on
DSA
control:
D
evice for
S
afety
A
utotest = before gate operation,
provided that this function is enabled. All of the safety
devices are tested and assessed to be free from any
obstraction, otherwise the operator is not allowed to
start.
Summary of Contents for Elpro 42
Page 34: ...Elpro 42 34 ...
Page 35: ...Elpro 42 35 ...