DIP-SWITCH - B
Operations
III
II
I
-
+
T.FUN
0s - 3s
1
2
3 4
ON
OFF
DIP-SWITCH - B
For setting working time of the electric lock or courtesy lamp connected
to the 14-15 outputs, put the Dip-switch B No.3 in ON and adjust the
working time by mean of trimmer T.FUN.
In this mode, the trimmer T.FUN enables you adjust electric lock working
time from 0s to 5s on the first half of trimmer travel. On the second half
of trimmer travel it allows you to connect a relé to 14-15 outputs for a
courtesy lamp working time control, adjustable from 30s to 5 min.
Once the electric lock or courtesy lamp working time is set, put all
Dip-switches B in OFF.
Operations
III
II
I
-
+
T.FUN
0s - 2s
1
2
3 4
ON
OFF
DIP-SWITCH - B
To adjust the braking duration put the Dip-Switch B No.1 in ON and set
the braking time by Trimmer T.FUN.
Once the calibration of braking duration is completed put all
Dip-switches B in OFF.
page 15
Dip - switch and trimmer of functions
Description
ELECTRONIC BRAKE FUNCTION
Electric lock:
14 15
12Vac power supply output
for
electric lock
15VA max or
relè for
courtesy lamp
control
or courtesy lamp:
ATTENTION:
In cases a motor with mechanical brake is used or a control board ELPRO 10 is replaced, the DIP-switch-A
No.12 has to be in OFF.
!
To enable the electronic brake function set the Dip-switch-A No. 12
in ON and adjust the electronic brake intensity by the selector in the figure.
The factory preset adjustments are suitable for most installations.
For a more precise regulation of the electronic brake, it is possible to set up various braking
parameters by following the
advanced instructions
bellow
.
ELECTRONIC BRAKE
INTENSITY
1
2
4
5
3
ON
OFF
1
2
3 4 5
6 7
8 9 10 11
12
DIP-SWITCH - A
Operations
Dip - switch and trimmer of functions
Function
ADVANCED INSTRUCTIONS FOR THE ELECTRONIC BRAKE
ATTENTION: the electronic brake is to be enabled by putting the Dip-switch No.12 in ON
Description
Braking time:
To set the additional stop time after braking put the Dip-switch B No.2
in ON and adjust the stop time by mean of trimmer T.FUN.
Once the calibration of additional stop time is completed put all
Dip-switches B in OFF.
N.W.: this function is enabled and adjustable even if the electronic
brake is disabled. It allows more time for the gate to reverse the
travel direction when safety devices as photocells or sensitive edges
are engaged, so as proper reverse movement is achieved, especially
for single-phase motors where high inertia is involved.
Additional stop
time after braking
when safety
devices are
activated:
meccanica
FADINI
37
SINGLE – THREE PHASE ELECTRONIC CONTROL BOARD WITH ELECTRONIC BRAKE