background image

page 9

meccanica

FADINI

GB

IN CASE OF FAILURE PLEASE MAKE SURE THAT:

- Power supply to the electronic control board is 230V ±10% or 400V ±10%
- Power supply to the electric motor is 230V ±10% or 400V ±10%
- All of the fuses is all right
- The photocell contacts are closed
- No voltage drop has occurred from the Elpro board to the electric motor
- The limit switches are properly connected and work correctly
- All of the NC contacts of the control board are all right.

IMPORTANT FOR THE INSTALLATION AND THE CORRECT FUNCTIONING:

- The control box must be installed in a dry and sheltered place; suitable holes are provided with the FADINI universal box for fitting purpose and in
  case any commercial box is used, this must be adequate to the job
- Make sure that power supply to the control board be 

230V ±10% or 400V ±10%

- Make sure that power supply to the electric motor be 

230V ±10% or 400V ±10%

- For distances longer than 50 metres increase the section of the wires
- Fit the mains to the control box with a high sensitivity, 0.03A, differential, magnetic-thermal circuit breaker
- Cables with 1.5mm² section wires are to be used for the power supply, electric motor and flasher for distances up to 50 m
- Cables with 1mm² section wires are to be used for the limit switches, photocells, push buttons and accessories
- If no photocells are used link out terminals 1 and 2
- If no stop button is used link out terminals 3 and 6
- Open/close motor run time trimmer must be always superior to the time actually required for the gate travel
N.W.: For applications such as light switching, CCTV, etc. use solid state relays to prevent the microprocessor from being affected

Diagnostic LEDs:
L ON     = 

Board on 230V or 400 V voltage and F1, F2, F3, F4, F5, F6 fuses all right

L0 OFF  = 

Pedestrian mode, it switches on by any pedestrian pulsing

L1 ON   = 

Pair photocells in closing not obstructed

L4 OFF  = 

Open, it switches on by any open pulse

L5 OFF  = 

Close, it switches on by any close pulse

L6 ON   = 

Stop, it switches off by any stop pulse

L7 OFF  = 

Radio, it switches on by any pulse from the transmitter/radio contact

L8 ON   = 

It switches off when Fc.C (limit switch closing = L-sw.C) is engaged, M1

L10 ON = 

It switches off when Fc.O. (limit switch opening = L-sw.O) is engaged, M1

L33 ON = 

Safety edge protecting closing not obstructed 

L34 ON = 

Safety edge or photocell protecting opening not obstructed 

ATTENTION: Before starting the electrical connections, check the voltage (230V or 400V) selector switch to be 
set correctly.
In cases a motor with mechanical brake is used or a control board ELPRO 10 is to be changed, the 
DIP-switch-A No.12 has to be in OFF.

!

Symbols

NC 

contact

NO 

contact

Led 

ON

Led 

OFF

Pilot light

Flasher

37

SINGLE – THREE PHASE ELECTRONIC CONTROL BOARD WITH ELECTRONIC BRAKE 
FOR SLIDING GATE AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES

General description:

 the electronic control box ELPRO 37 has been developed to provide a reliable unit to control sliding gate automatic systems with 

or without electronic brake and limit switches. Single-phase 230V 50/60Hz or Three-phase 400V 50/60Hz  ELPRO 37 complies with the Low Voltage Norms 
2006/95 CE and Electro-magnetic Compatibility 2004/108/CE. Installation is recommended by qualified technical installation agents in compliance with 
the existing regulations. The manufacturer is not liable for any incorrect use of this appliance; and also reserves the right to change and update it without 
previous notice.

ELECTRIC MOTOR

power supply

M1

L

TRANSFORMER

UNL

ON

OFF

1

2

3 4 5

6 7

8 9 10 11 12

DIP-SWITCH - A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

PLUG-IN
RADIO

CARD
CONNECTOR

pedestrian

photocell

in closing 

radio contact

common

open

close

stop

Indication lamp 24

V

 

ma

x 3

W

 

24

V

ac output 

 (ma

x load:

n°1 radio recei

v

er

n°3 pairs photocells

po

w

er suppl

y for 

electric lock 15

V

A

 ma

or indication lamp

230Vac

 OUTPUT for 

flashing lamp

max 25W

Single-phase control board 

power supply

230V - 50/60Hz ±10%

24V AC output 

for photocell TX 

enabling 

DSA control

NC

common

NEUTR

A

L

LI

V

E

26

27

28

CARD
CONNECTOR FOR

TRAFFIC LIGHTS
(Item 7282L)

+

_

Power supply

24V - 50mA max.

230V

400V

ON

OFF

1

2

3 4

DIP-SWITCH - B

ELPRO 3

7

UNL

E 37

L0

L1

L4 L5 L6 L7 L8

L10

RUN 

TIME 

 0s - 120s

DWELL 

TIME

1s - 220s

  

PEDESTRIAN

1s - 45s

-

+

-

+

-

+

-

+

T.FUN

L33 L34

32 33 34

SAFETY EDGE

in OPENING

8,2 k

Ω

or NC

common

JA

1 2

SETUP
EDGE
TYPE

JB

1 2

Resistive contact 
8,2 k

Ω

 or NC

NOTE:
The green LEDs must
always be on.

L.s.O

L.s. C

common

8,2 k

Ω or 

NC

SAFETY EDGE

in CLOSING

ELECTRONIC BR

A

KE

INTENSIT

Y

1

2

4

5

3

F3=8

A

 net

w

ork

F2=8

A

 net

w

ork

F1=8

A

 net

w

ork

16

17

18

19 20

21

22

23

F5=630

A

 flashing 

light protection

F4=2A transformer and  
       electronic brake       
       protection

38
39

F6=2A protection
       24V

Three-phase control board 

power supply

400V - 50/60Hz ±10%

LI

V

E

LI

V

E

LI

V

E

Capacitor for 

single-phase motors

EARTH CONNECTION

Summary of Contents for Elpro 37

Page 1: ...T TIME ELECTRIC LOCK OUTPUT Elektronische Steuerung einphasig dreiphasig mit Elektrobremse f r Schiebetore und Automationen mit oder ohne Endschalter max 1 5 PS dreiphasig oder 1 0 PS einphasig ELEKTR...

Page 2: ...ty edge or photocell protecting opening not obstructed ATTENTION Before starting the electrical connections check the voltage 230V or 400V selector switch to be set correctly In cases a motor with mec...

Page 3: ...on by any radio pulse Dip Switch A 1 ON Photocells stop gate in opening 2 ON Radio no reversing in opening 3 ON Automatic closing 4 ON Pre flashing enabled 5 ON Radio step by step 6 ON Dead man 7 ON F...

Page 4: ...goes off Safety edge in opening In series if safety edges are mechanical N C 32 33 Selecting functioning JB JB 1 2 Gate travel is reversed on Opening and Closing for a short spell 1 2 Gate travel is...

Page 5: ...0 HP or three phase 400V max 1100W 1 5 HP 24V Output FA DIN I Astro 43 FA D I N I 24Vac OUTPUT max load No 3 pairs photocells No 1 radio receiver No 1LED Chis 37 Chis E 37 key switch Instructions are...

Page 6: ...ed Yellow Green Fuse 1A Common 63 64 65 66 60 61 Optional Traffic lights plug in card for 230V Lamps Item 7282L Dip switch A 4 ON Pre flashing enabled traffic lights red yellow green 4 OFF Pre flashin...

Page 7: ...L CLOCK Connect the clock NO contact to OPEN terminals No 4 and COMMON No 3 and activate automatic closing by setting Dip Switch No 3 ON How it works program the opening time on the clock At the prese...

Page 8: ...brake function set the Dip switch A No 12 in ON and adjust the electronic brake intensity by the selector in the figure The factory preset adjustments are suitable for most installations For a more p...

Page 9: ...10 2016...

Reviews: