![background image](http://html1.mh-extra.com/html/fadini/elpro-37/elpro-37_manual_3170455003.webp)
page10
Key-switch:
Photocells in
closing:
1
DIP-SWITCH-A N° 1:
ON:
stop gate/s in opening and reverse
travel in closing when cleared
OFF:
no stop in opening and reverse travel in
closing when obstructed
Radio Contact
(step by step mode):
Any NO connection to these two terminals
will perform the following:
- Opening only:
Dip 2=ON and Dip 5=OFF
- Gate travel reversing by any pulse
Dip 2=OFF and Dip 5=OFF
- Step by step: Open-Stop-Close-Stop
Dip 2=OFF and Dip 5=ON
- No new pulse is accepted in opening. In
Dwell phase and in closing any new pulse
stops and reverses gate travel:
Dip 2=ON and Dip 5=ON
ON:
It does not stop and reverse gate travel
in opening
OFF:
always stops & reverses in opening
2
ON:
step by step with intermediate stop
OFF:
gate travel reversed by any radio pulse
5
DIP-SWITCH-A N°2 and N°5:
All NC contacts of safety
accessories such as
Photocells (receivers)
must be connected in
series with terminals
1 and 2
Accessory
Electrical connections
NO and NC contacts to be connected
to the respective terminals in the key-
or button-switches.
All of the possible setting combinations
are described in the instructions sheets
included with the respective control
accessories
NC
NC
1 2
3 4 5 6
F A
D
I N
I
F A
D
I N
I
NC
OPEN
CLOSE
S
T
OP
COMMON
RADIO
CONTACT
COMMON
3
7
L1 ON
=
no obstacle, it goes off
in case of obstruction
L4 OFF =
no OPENING contact, it goes on
whenever an opening pulse is given
L5 OFF =
no CLOSING contact, it goes on
whenever a closing pulse is given
L6 ON =
STOP contact closed, it goes
off whenever a stop pulse is given
L7 OFF =
no RADIO contact, it goes on by
any radio pulse
Dip-Switch A
1 = ON
Photocells stop gate in opening
2 = ON
Radio, no reversing in opening
3 = ON
Automatic closing
4 = ON
Pre-flashing enabled
5 = ON
Radio step-by-step
6 = ON
Dead man
7 = ON
Flasher off in dwell time in automatic
8 = ON
Gate re-closing in opening and dwell on photocells engaging
9 =
ON
DSA control of photocells before any movement
10 = ON
Photocells not obstructed before moving
11 = Blank
12 = ON
Electronic brake enabled
Dip-Switch B
1 = ON
set braking duration
2 = ON
set additional stop time after braking when safety devices are activated
3 = ON
set electric lock or courtesy lamp duration
4 = OFF
Blank
1
2
3 4
ON
OFF
DIP-SWITCH - B
Dip-Switch setting and LED indication of functions
Output for a 24V max 3W indication lamp
showing the status of the system:
Lamp
On
= Gate open
Lamp
Off
= Gate closed
0.5s (fast)
flashing = gate closing
1s (normal)
flashing = gate opening
Indication lamp
output
24V- max 3W:
COMMON
3
11
12 13
24Vac output
max. load:
n°1 radio receiver
n°3 pairs photocells
FA
DINI
!
Limit switches:
L8 ON =
OFF on engaging L.sw. closing
L10 ON =
OFF on engaging L.sw. opening
8 9 10
IMPORTANT:
if
no limit switches
are involved,
link out terminals
8 - 9 - 10.
Limit switches ( L-sw.) must have
normally closed contacts.
meccanica
FADINI
37
common
Opening
Limit s
w
itch
Closing
Limit s
w
itch
ATTENTION: Before starting the electrical connections, check the voltage (230V or 400V) selector switch to be
set correctly.
In cases a motor with mechanical brake is used or a control board ELPRO 10 is replaced, the DIP-switch -A
No.12 has to be in OFF.
SINGLE – THREE PHASE ELECTRONIC CONTROL BOARD WITH ELECTRONIC BRAKE
FOR SLIDING GATE AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES
GB
ON
OFF
1
2
3 4 5
6 7
8 9 10 11 12
DIP-SWITCH - A
F A
D
I N
I
1
2
3
4
5
6
7
8
9
A
B
S
TOP
Summary of Contents for Elpro 37
Page 9: ...10 2016...