background image

page10

Key-switch:

Photocells in 
closing:

1

DIP-SWITCH-A N° 1:

ON: 

stop gate/s in opening and reverse     

        travel in closing when cleared

OFF: 

no stop in opening and reverse travel in

        closing when obstructed

Radio Contact
(step by step mode):

Any NO connection to these two terminals
will perform the following:

- Opening only: 

Dip 2=ON and Dip 5=OFF

- Gate travel reversing  by any pulse

Dip 2=OFF and Dip 5=OFF

- Step by step: Open-Stop-Close-Stop

Dip 2=OFF and Dip 5=ON

- No  new pulse is accepted in opening. In
Dwell phase and in closing any new pulse
stops and reverses gate travel:

Dip 2=ON and Dip 5=ON

ON:  

It does not stop and reverse gate travel

        in opening

OFF: 

always stops & reverses in opening

2

ON: 

step by step with intermediate stop

OFF:

 gate travel reversed by any radio pulse

5

DIP-SWITCH-A N°2 and N°5:

All NC contacts of safety
accessories such as
Photocells (receivers)
must be connected in
series with terminals
1 and 2

Accessory

Electrical connections

NO and NC contacts to be connected
to the respective terminals in the key-
or button-switches.
All of the possible setting combinations
are described in the instructions sheets
included with the respective control
accessories

NC

NC

1 2

3 4 5 6

F A

D

I N

I

F A

D

I N

I

NC

OPEN

CLOSE

S

T

OP

COMMON

RADIO

CONTACT

COMMON

3

7

L1 ON 

no obstacle, it goes off

               in case of obstruction

L4 OFF = 

no OPENING contact, it goes on

whenever an opening pulse is given

L5 OFF = 

no CLOSING contact, it goes on

whenever a closing pulse is given

L6 ON = 

STOP contact closed, it goes

off  whenever a stop pulse is given

L7 OFF = 

no RADIO contact, it goes on by 

any radio pulse

Dip-Switch A
1  = ON 

Photocells stop gate in opening

2  = ON

 Radio, no reversing in opening

3  = ON

 Automatic closing

4  = ON

 Pre-flashing enabled

5  = ON

 Radio step-by-step

6  = ON

 Dead man

  7 = ON 

Flasher off in dwell time in automatic

  

8 = ON 

Gate re-closing in opening and dwell on photocells engaging

  

9 =

 

ON 

DSA control of photocells before any movement

10 = ON

 Photocells not obstructed before moving

11 = Blank
12 = ON 

Electronic brake enabled

Dip-Switch B
 1 = ON

 set braking duration

 2 = ON 

set additional stop time after braking when safety devices are activated

 3 = ON 

set electric lock or courtesy lamp duration

 

4 = OFF 

Blank

1

2

3 4

ON

OFF

DIP-SWITCH - B 

Dip-Switch setting and LED indication of functions

Output for a 24V max 3W indication lamp
showing the status of the system:
Lamp 

On

 = Gate open

Lamp 

Off 

= Gate closed

0.5s (fast)

 flashing = gate closing

1s (normal)

 flashing = gate opening

Indication lamp
output
24V- max 3W:

COMMON

3

11

12 13

24Vac output 

max. load:

n°1 radio receiver

n°3 pairs photocells

FA

DINI

!

Limit switches:

L8 ON = 

OFF on engaging L.sw. closing 

L10 ON = 

OFF on engaging L.sw. opening 

8 9 10

IMPORTANT: 

if 

no limit switches

are involved,

 link out terminals

8 - 9 - 10.
Limit switches ( L-sw.) must have
normally closed contacts.

meccanica

FADINI

37

common

Opening 

Limit s

w

itch

Closing 

Limit s

w

itch

ATTENTION: Before starting the electrical connections, check the voltage (230V or 400V) selector switch to be 
set correctly.
In cases a motor with mechanical brake is used or a control board ELPRO 10 is replaced, the DIP-switch -A
No.12 has to be in OFF.

SINGLE – THREE PHASE ELECTRONIC CONTROL BOARD WITH ELECTRONIC BRAKE 
FOR SLIDING GATE AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES

GB

ON

OFF

1

2

3 4 5

6 7

8 9 10 11 12

DIP-SWITCH - A 

F A

D

I N

I

1

2

3

4

5

6

7

8

9

A

B

S

TOP

Summary of Contents for Elpro 37

Page 1: ...T TIME ELECTRIC LOCK OUTPUT Elektronische Steuerung einphasig dreiphasig mit Elektrobremse f r Schiebetore und Automationen mit oder ohne Endschalter max 1 5 PS dreiphasig oder 1 0 PS einphasig ELEKTR...

Page 2: ...ty edge or photocell protecting opening not obstructed ATTENTION Before starting the electrical connections check the voltage 230V or 400V selector switch to be set correctly In cases a motor with mec...

Page 3: ...on by any radio pulse Dip Switch A 1 ON Photocells stop gate in opening 2 ON Radio no reversing in opening 3 ON Automatic closing 4 ON Pre flashing enabled 5 ON Radio step by step 6 ON Dead man 7 ON F...

Page 4: ...goes off Safety edge in opening In series if safety edges are mechanical N C 32 33 Selecting functioning JB JB 1 2 Gate travel is reversed on Opening and Closing for a short spell 1 2 Gate travel is...

Page 5: ...0 HP or three phase 400V max 1100W 1 5 HP 24V Output FA DIN I Astro 43 FA D I N I 24Vac OUTPUT max load No 3 pairs photocells No 1 radio receiver No 1LED Chis 37 Chis E 37 key switch Instructions are...

Page 6: ...ed Yellow Green Fuse 1A Common 63 64 65 66 60 61 Optional Traffic lights plug in card for 230V Lamps Item 7282L Dip switch A 4 ON Pre flashing enabled traffic lights red yellow green 4 OFF Pre flashin...

Page 7: ...L CLOCK Connect the clock NO contact to OPEN terminals No 4 and COMMON No 3 and activate automatic closing by setting Dip Switch No 3 ON How it works program the opening time on the clock At the prese...

Page 8: ...brake function set the Dip switch A No 12 in ON and adjust the electronic brake intensity by the selector in the figure The factory preset adjustments are suitable for most installations For a more p...

Page 9: ...10 2016...

Reviews: