Watchdog Configuration
Watchdog 1 Function
This field specifies the Enabled or Disabled of the Watchdog Function.
Available Options:
Disabled and Enabled
Default setting
: Disabled
Watchdog 1 Signal Select
This field is the Select IRQ, NMI or Reset signal trigger of onboard watchdog.
Available Options:
IRQ 3 ~ IRQ12, IRQ14, IRQ15, NMI, and Reset
Default setting
: Reset
Watchdog 1 Timer
This field is the Select when IRQ, NMI or Reset signal trigger timer of onboard
watchdog.
Available Options:
2 Sec ~ 512 Sec
Default setting
: 64 Sec
Note
: Please refer to the section of the “
” in the Chapter 5 “Driver
and Utility” for the detail description of the Watchdog ports register.