background image

                                                                                                                                              

7 < 

<

 

<

 

<

 

 

 

3.4

 

 

Cleaning and maintenance 

After the heating season, it is recommended to clean the fireplace and the flue gas pipes carefully. 
Any dropping heating performance is almost always the consequence of the strong contamination of 
the flues. For cleaning, the baffle plate (Picture 7) is to be pulled forward. This way, the flues can 
be cleaned from the inside or – after removing the flue gas pipe – from above. After cleaning, the 
baffle plate (Picture 7) is be pushed back fully again.    
Warning! 
Following every heating season you are advised to examine the fireplace thoroughly. If any repair or 
reconditioning  is  needed,  please,  contact  your  local  dealer  in  a  timely  manner,  and  specify  the 
model number and serial number of your equipment (as seen on the model plate). 
External surfaces may be maintained only after the fireplace cooled down, and following the first 
commissioning.  Use  cold  water  for  cleaning,  or  soap,  washing  ingredient  in  extraordinary  cases, 
then wipe it dry. Before its first use, clean the ROBAX inspection glass with a wet and clean cloth, 
and then  put a few drops of glass–ceramics cleaner onto both sides of the glass, and spread them 
with  the  use  of  kitchen  paper  tissues.  It  provides  an  invisible  film  on  the  valuable  surface  of  the 
Robax  glass.  This  film  helps  to  keep  the  glass  clean,  and  facilitates  regular  cleaning  operations. 
ROBAX S for slightly contaminated surfaces – a commercially available glass surface cleaning agent – 
may as well be used for the cleaning of the medium or strongly contaminated glass surfaces of the 
fireplace. Towards this end, spray small quantities of the agent to the cold surfaces, spread it, and 
wash it down with a wet cloth, followed by drying with a clean, soft cloth. In case there are sticky 
fuel  deposits  on  these  surfaces,  first  scale  simply  them  with  a  ceramic-plate  scraper  held  in  flat 
angle, and then clean the surfaces as described above.  
Cleaning of the ceramic surfaces dirt and grease are to be removed with soap and water. 
Cleaning of the soapstone: the soapstone is a natural stone, therefore minor colour differences may 
occur ; as it is normal, they may not serve as a basis for quality complaints! To clean the soapstone 
from dirt and fat with water and soap, as well as small scratches, use sand paper (grain size 240).  
Warning: Under no circumstances you may use sponge, scouring, aggressive or scratching cleaning 
agents! If the grate is blocked so that the equipment cannot serve the intended function, the grate 
is to be removed for cleaning.  

 

 

 

 

 

 

 

 

 

 

Remove The transport 

paper roll 

Summary of Contents for Oscar

Page 1: ...Oscar 40011236 1143 Installation manual ENG ENG...

Page 2: ...coal briquette see user instructions Never use liquid igniters Use special ignition materials or wood wool for the kindling of the fire Never use wastes fine wooden chips mulch coal debris particle bo...

Page 3: ...ng air connections to other rooms with air openings at least 150 cm2 Ensure to keep proper lateral and rear distances from combustible parts and materials The associated values are specified in these...

Page 4: ...4 L Ash bin Furnace chamber door Storage Flue connection...

Page 5: ...ting value appr KJ kg Hard wood 19 500 Soft wood 14 600 Brown coal 11 500 3 1 Table 1 Filling quantities Split billet max Length 35 cm max 2 billet per filling appr 1 7 kg Brown coal briquette max 1 7...

Page 6: ...wise problems with draught can occur at other equipment leading to the same chimney Warning When opening the furnace chamber door any incorrect handling or insufficient draught may induce smoke Always...

Page 7: ...tchen paper tissues It provides an invisible film on the valuable surface of the Robax glass This film helps to keep the glass clean and facilitates regular cleaning operations ROBAX S for slightly co...

Page 8: ...r chimney and also that the doors of other fire places leading to the same chimney are closed and sealed properly Make sure that the chimney cleaning joints are sealed properly Too long and leaky smok...

Page 9: ...opening air connections to other rooms with air openings at least 150 cm2 4 2 Distances All the combustible materials furniture or e g decoration materials that are in the close environment of the fir...

Page 10: ...ustible materials in the building Provided that the interconnecting pieces have a non combustible coating of minimum 2 cm the distance from combustible materials may be at least 10 cm If the interconn...

Page 11: ...11 L Correct Incorrect...

Page 12: ...ith a stop cock close to the stove Of course heating is also possible with the air of the room see Item 2 2 Germany The stoves use room air for combustion and a sufficient supply of combustion air is...

Page 13: ...scar Nominal performance 8 Kw Heating capacity m3 under favourable less favourable not favourable heating circumstances according to 18893 TAB2 DIN standard 182 105 71 Flue gas values fuel Flue gas st...

Page 14: ...ctives and the following standards is hereby certified EN 13240 2005 ppa Munich 20 07 2009 Proper binding signature This Declaration certified compliance with the above referenced directives yet canno...

Page 15: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501...

Reviews: