Foreword 

 
Dear Customer! 
Thank you for choosing our product! 
By purchasing this product you receive guarantee for 

 

good quality originating from the usage of the finest and proven materials, 

 

operating security which is controlled according to German and European norms (Corresponds to 
the standards DIN 18891 Construction Shape 1 and EN 13240.), 

 

long life ensured by the robust structure. 

In order to be able to use your new fireplace for a long time please read the following instructions 
manual. You will find all the necessary information in it and some additional advice.  
 

2

 

FETY INSTRUCTIONS 

 

This equipment has been certified under the requirements of standard DIN EN 13240 or DIN EN 
12815 (see the model plate). 

 

For setting purposes and connection to the chimney, the fire protection requirements as 
prescribed in the given locations, as well as standards DIN 4705, DIN EN 13384, DIN EN 1856-2 
and DIN EN 15287 should be complied with. For the problem-free functioning of the equipment, 
the chimney that the fireplace is to be connected to has to be in perfect conditions (Germany). 

 

Before the first commissioning and connection to the chimney, these user instructions are to be 
read thoroughly, and the competent chimney sweeper has to be informed. 

 

It is recommended to use clean cotton gloves for the setting of the equipment in order to avoid 
the appearance of fingerprints that would be hard to eliminate later on. 

 

In order to keep the air clean and maintain the equipment properly, the maximum fuel 
quantities specified in these safety instructions may not be exceeded, and the doors of the 
eqipment have to be kept closed, otherwise the equipment may overheat, leading to damage. 
No guarantee is provided for such damage. 

 

During operations, the doors of the equipment are to be kept always closed. 

 

Permissible fuels: 
- natural wood (max. 35 cm in length) 
- brown coal briquette (see user instructions) 

 

Never use liquid igniters. Use special ignition materials or wood wool for the kindling of the 
fire.  

 

Never use wastes, fine wooden chips, mulch, coal debris, particle board wastes, wet wood or 
wood treated with wood-protective agents, paper or cardboard or similar materials for burning. 

 

Upon the first kindling, smoke and unpleasant smell may be generated. Always ensure the 
proper ventilation of the room (by opening windows and doors), and heat the fireplace at 
maximum rated heating performance. If with the first heating the maximum temperature is not 
reached, the above-mentioned effects may as well arise later on. 

 

The operating elements and adjustment units are to be used as described in these user 
instructions. If the equipment is hot, use auxiliaries or protective gloves for the handling of the 
equipment. 

 

When opening the furnace chamber door, any incorrect handling or insufficient draught may 
induce smoke. Always ensure that the furnace chamber door may be opened only slowly, first 
just to a small extent, and then fully after a few seconds. In addition, if you intend to put 
additional fuel into the fire, before the opening of the door only there may be only ember bed 
in the burning space, i.e. no flames may be visible. 

 

In heating mode, the surfaces, inspection glasses and handles may become very hot. Warn 
children of these threats, and keep them away from the fireplace when heated. 

 

Ensure that the ashtray should be fully inserted, and in particular never remove hot ash from 
the fireplace (fire risk). 

 

In transitional periods, chimney draught may drop, resulting in the imperfect suction of the 
generated flue gases. In such cases, the fireplace is to be filled with smaller quantities of fuel, 
preferably wooden chips or wood wool, and it is to be commissioned under control with the 
stabilization of the chimney draught. The fire grate should always be kept clean. 

 

After the heating season, it is recommended to have the equipment inspected by an expert. It 
is also advisable to clean the routes of flue gases and pipes. 

Summary of Contents for Oscar

Page 1: ...Oscar 40011236 1143 Installation manual ENG ENG...

Page 2: ...coal briquette see user instructions Never use liquid igniters Use special ignition materials or wood wool for the kindling of the fire Never use wastes fine wooden chips mulch coal debris particle bo...

Page 3: ...ng air connections to other rooms with air openings at least 150 cm2 Ensure to keep proper lateral and rear distances from combustible parts and materials The associated values are specified in these...

Page 4: ...4 L Ash bin Furnace chamber door Storage Flue connection...

Page 5: ...ting value appr KJ kg Hard wood 19 500 Soft wood 14 600 Brown coal 11 500 3 1 Table 1 Filling quantities Split billet max Length 35 cm max 2 billet per filling appr 1 7 kg Brown coal briquette max 1 7...

Page 6: ...wise problems with draught can occur at other equipment leading to the same chimney Warning When opening the furnace chamber door any incorrect handling or insufficient draught may induce smoke Always...

Page 7: ...tchen paper tissues It provides an invisible film on the valuable surface of the Robax glass This film helps to keep the glass clean and facilitates regular cleaning operations ROBAX S for slightly co...

Page 8: ...r chimney and also that the doors of other fire places leading to the same chimney are closed and sealed properly Make sure that the chimney cleaning joints are sealed properly Too long and leaky smok...

Page 9: ...opening air connections to other rooms with air openings at least 150 cm2 4 2 Distances All the combustible materials furniture or e g decoration materials that are in the close environment of the fir...

Page 10: ...ustible materials in the building Provided that the interconnecting pieces have a non combustible coating of minimum 2 cm the distance from combustible materials may be at least 10 cm If the interconn...

Page 11: ...11 L Correct Incorrect...

Page 12: ...ith a stop cock close to the stove Of course heating is also possible with the air of the room see Item 2 2 Germany The stoves use room air for combustion and a sufficient supply of combustion air is...

Page 13: ...scar Nominal performance 8 Kw Heating capacity m3 under favourable less favourable not favourable heating circumstances according to 18893 TAB2 DIN standard 182 105 71 Flue gas values fuel Flue gas st...

Page 14: ...ctives and the following standards is hereby certified EN 13240 2005 ppa Munich 20 07 2009 Proper binding signature This Declaration certified compliance with the above referenced directives yet canno...

Page 15: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501...