The flooring under the fire-place   

Flooring made of combustible materials like carpet, parquet floor or cork shall be protected by a 
shield of non-combustible material (e.g. ceramics-, stone-, glass-floor or metal) placed under the 
fire-place reaching 50 cm in front of the furnace chamber and 30 cm besides.  

Joint of the chimney

 

WARNING: 
Before connecting the fireplace to the chimney, seek advice from the competent chimney sweeper! 
The  connecting  elements  should  be  attached  to  the  equipment  and  to  each  other  in  a  properly 
sealed and stable manner. They may not hang into the unobstructed cross-section of the chimney. 
The  interconnecting  piece  between  the  chimney  and  the  fireplace  should  be  of  the  same  cross-
section  size  as  the  pipe  stub  of  the  fireplace.  Horizontal  connecting  pieces  should  ascend  to  the 
chimney in 10°. Pipes that are not heat-protected or not led vertically may not be longer than 1 m. 
There should be a minimum distance of 40 cm kept between the connection pieces of the fireplace 
and  combustible  materials  in  the  building.  Provided  that  the  interconnecting  pieces  have  a  non-
combustible coating of minimum 2 cm, the distance from combustible materials may be at least 10 
cm. If the interconnecting pieces are led through equipment or furnishing made from combustible 
materials, they have to be covered with a protecting tube made from any non-combustible material 
in a distance of at least 20 cm, or they have to be coated with any non-combustible material with 
low heat conductance in a minimum range of 20 cm. 
Smaller  distances  to  combustible  materials  are  permissible  if  it  is  ensured  that  at  the  rated 
performance of the fireplace the temperature cannot rise over 85°C at the combustible equipment 
and furnishings. 
WARNING: 
The  connection  of  the  fireplace  to  the  chimney  is  not  permissible  if  the  effective  height  of  the 
chimney is less than 4 m, or 5 m with multiple loading (see the details of chimney calculations on 
page 29). 
To  the  chimney  that  the  fireplace  uses,  a  maximum  of  two  other  fireplaces,  ovens  may  be 
connected. 
 
 
 

 

 

 

 

 

 

 

 

 

The fire-place can usually be 

jointed

 

to the chimney with an arch.

 

When the chimney draught is weak 

the

 

fire

–place must be jointed  to the 

chimney through a vertical smoke tube.

 

Summary of Contents for Oscar

Page 1: ...Oscar 40011236 1143 Installation manual ENG ENG...

Page 2: ...coal briquette see user instructions Never use liquid igniters Use special ignition materials or wood wool for the kindling of the fire Never use wastes fine wooden chips mulch coal debris particle bo...

Page 3: ...ng air connections to other rooms with air openings at least 150 cm2 Ensure to keep proper lateral and rear distances from combustible parts and materials The associated values are specified in these...

Page 4: ...4 L Ash bin Furnace chamber door Storage Flue connection...

Page 5: ...ting value appr KJ kg Hard wood 19 500 Soft wood 14 600 Brown coal 11 500 3 1 Table 1 Filling quantities Split billet max Length 35 cm max 2 billet per filling appr 1 7 kg Brown coal briquette max 1 7...

Page 6: ...wise problems with draught can occur at other equipment leading to the same chimney Warning When opening the furnace chamber door any incorrect handling or insufficient draught may induce smoke Always...

Page 7: ...tchen paper tissues It provides an invisible film on the valuable surface of the Robax glass This film helps to keep the glass clean and facilitates regular cleaning operations ROBAX S for slightly co...

Page 8: ...r chimney and also that the doors of other fire places leading to the same chimney are closed and sealed properly Make sure that the chimney cleaning joints are sealed properly Too long and leaky smok...

Page 9: ...opening air connections to other rooms with air openings at least 150 cm2 4 2 Distances All the combustible materials furniture or e g decoration materials that are in the close environment of the fir...

Page 10: ...ustible materials in the building Provided that the interconnecting pieces have a non combustible coating of minimum 2 cm the distance from combustible materials may be at least 10 cm If the interconn...

Page 11: ...11 L Correct Incorrect...

Page 12: ...ith a stop cock close to the stove Of course heating is also possible with the air of the room see Item 2 2 Germany The stoves use room air for combustion and a sufficient supply of combustion air is...

Page 13: ...scar Nominal performance 8 Kw Heating capacity m3 under favourable less favourable not favourable heating circumstances according to 18893 TAB2 DIN standard 182 105 71 Flue gas values fuel Flue gas st...

Page 14: ...ctives and the following standards is hereby certified EN 13240 2005 ppa Munich 20 07 2009 Proper binding signature This Declaration certified compliance with the above referenced directives yet canno...

Page 15: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501...

Reviews: