COM

FABER -  

JP

WORKING MODE

The FAULT output in normal operating conditions supplies a positive output (max 2,5A).
In faulty conditions the FAULT output is turned off.

Connecting this signal to a system that puts   the installation in safety conditions it is possible to stop the machine 
operations in case of joystick fault.

The BYPASS output is turned on (positive output max 2,5 mA) every time the joystick is moved from the zero position. 
When the joystick is released the output is turned off with a 0,4 seconds delay (programmable).

The red and the green LEDs under the joystick are used to show different working conditions. 
In normal operating conditions, the red LED is used as a power supply LED; it is turned on when the power 
supply is present.

Red LED is turned off for a little while when bypass output is turned on or off.

In case of faulty operations the two LEDs flash in various modes depending on the fault type:

RED LED

Two flash:

 system turned on with the joystick not at zero position. Outputs will stay turned off. It is necessary 

to turn off  the joystick and turn it on again releasing the lever.

Four flash:

 Internal error on the magnetic sensors (excessive signal difference between the two probes of 

the same channel) or movement of the lever too fast. It remains blocked until it is turned off.

Five flash:

 Internal error on the magnetic sensors or on the third axis input (signal out of range). It remains 

blocked until it is turned off.

Seven flash:

 Calibrating parameters not valid. It remains blocked until it is turned off.

GREEN LED

When you move the joystick, the green led is turned on proportional to the greater current supplied. If joystick 
is not plugged or a wired is broken, the green LED will stay turned off because no current will be supplied.

RED and GREEN LED at the same time

One flash at second:

 joystick has to be calibrated. Follow the appropriate procedure (reserved).

VIRTUAL CROSS

PWM outputs are turned on to regulate the current that flows in the load proportional to the movements of the 
joystick. If you activate the "virtual cross" function, you will be able to move joystick in just one direction at a time: 
the first manoeuvre done forbids all the other manoeuvres until the joystick will return at rest position.
Otherwise, if the "virtual cross" function is not activated, you will be able to do two manovreus at the same time, 
by moving the joystick in diagonal direction.
The "virtual cross" fuction, if activated, is referred only to the two principal axis; the third axis, if present, will 
continue to work indipendently to the two other axis.

SIGNALS

Page 2 / 8

2 / 3 axis joystick 
with power outputs (PWM)

Summary of Contents for JP

Page 1: ...ming Device TECHNICAL SPECIFICATIONS DESCRIPTION JP is a 2 or 3 axis electronic joystick with power outputs able to directly control up to 6 proportional solenoid valves with PWM outputs proportional...

Page 2: ...y turned off It is necessary to turn off the joystick and turn it on again releasing the lever Four flash Internal error on the magnetic sensors excessive signal difference between the two probes of t...

Page 3: ...es histeresis For the programming steps from 1 to 4 it is necessary move the joystick to choose the manoeuvre which has to be regulated Actually it is possible to set different values of min max curre...

Page 4: ...1 42028 Poviglio RE Italy Tel 39 0522 960428 Fax 39 0522 969644 www fabercom it Tecnico Prodotti Manipolatore Jp Documenti SM Manuale JP_v102_ie cdr 11 01 07 FABER COM srl Via Romana 36 1 42028 Povig...

Page 5: ...EN BLUE BLUE BLUE BLUE BLUE BLUE ORANGE ORANGE YELLOW BLAK Thumbwheel connector Z axis Serial Port for PRG2 programming keyboard 2 diagnostic LED Bottom view 14 poles MOLEX Minifit jr connector for su...

Page 6: ...a Xb Yb Zb Fault Fast Slow 1 12V 24V 1 Bypass Za Ya Xa Xb Yb Zb Fast Slow PWM unico 12V 24V 1 Bypass Fast Slow PWM unico Za Ya Xa Xb Yb Zb 12V 24V JP Page 6 8 CONFIGURATION EXAMPLES 2 proportional ind...

Page 7: ...co Prodotti Manipolatore Jp Documenti SM Manuale JP_v102_ie cdr 11 01 07 FABER COM srl Via Romana 36 1 42028 Poviglio RE Italy Tel 39 0522 960428 Fax 39 0522 969644 www fabercom it COM FABER JP Page 7...

Page 8: ...ard At the end of the programming phase it is necessary to save parameters in memory by pushing contemporaneously the PREV and the NEXT buttons otherwise all the modifications will be lost when the de...