Country UK/IRL
UK/IRL
UK/IRL
UK/IRL
Cat.
II2H3+
II2H3+
II2H3+
II2H3+
Appliance
Silence / Feeling
/ Sense
Silence / Feeling
/ Sense
Serene Serene
logburner
logburner logburner logburner
Appliance type
B11BS B11BS B11BS
B11BS
Reference gas
G20 G31 G20
G31
Input (nett)
[kW]
6,9 6,5 6.2
6.2
Efficiency class
2 2 2
2
Inlet pressure
[mbar]
20 37 20
37
Gas Rate (15º C and
1013 mbar)
m3/h
0,72 0,24
0.65
0.24
Reference burner
pressure
[mbar]
8 15,4
10.5
21
Injector size
[mm]
2x1,60 1x 1,50
3 x 1,00
3 x 1.40
3 x 0.90
reduced input
restrictor
[mm]
1,8 1,1
1.80
1.00
Pilot assembly
Type
SIT 160
SIT 160
SIT 160
SIT 160
code
Nr 51
Nr 30
Nr 51
Nr 30
Flue size (min)
100mm 100mm 100mm
100mm
Min Flue height
3 m
3 m
3 m
3 m
Gas control
GV36-C5AOEHC68M GV36-C5AODHC68M GV36-C5AODHC68M GV36-C5AODHC68M
Remote control
adapter
230VAC/50HZ/5VA 230VAC/50HZ/5VA
N.A.
N.A.
Voltage adapter
[V]
4,5 4,5
1 x 9V
1 x 9V
Batteries RC
2 x LR03 Alkaline 2 x LR03 Alkaline
2 x LR03 Alkaline
2 x LR03 Alkaline
Gas connection
8mm nut & olive
8mm nut & olive
8mm nut & olive
8mm nut & olive
Dimensions: see
table 1