4. INSTRUCTIONS FOR INSTALLATION
4.1 Gas connection
1)
Installation pipes should be in accordance with BS 6891 (IRL IS813).
Pipework from the meter to the appliance must be of adequate size.
2)
The complete installation including the meter must be tested for
soundness and purged as described in the above code.
3)
Isolation must be provided in the supply to facilitate servicing.
4)
The connection should be made in 8 mm copper or similar semi
flexible tube (max. 1 meter). Ensure that the gas pipe does not
interfere with the removal or replacement of the burner tray of the
controls.
5)
The supply gas feed line should enter the appliance through one of
the openings in the appliance case. Openings are at the back and
right side.
6)
The gas connection is nut and olive suitable for 8 mm pipe.
7)
Where a gas pipe passes through a void, wall or cavity it must be
fully enclosed in a sleeve.
Gas supply routes when fire is fitted in a deep surround
A & B = Behind surround – Sleeve pipe through surround
C = Through wall – Pipe must be sleeved and sealed to fire
fig. 3