25
4)
Check the ignition of the main burner on low and high setting.
5)
Turn knob B clockwise till
z
. The main burner is off.
6)
Turn the knob A to
z
. The pilot should go out.
6.3 Spillage test
1)
Carry out the lighting procedure and turn the fire to high.
2)
Allow to warm up for 15 minutes and then using a smoke match with
holder set 100% inside the square tube on the top of the appliance
between the trim and the glass frame. The installation is satisfactory
if most of the smoke is drawn into the tube.
3)
Repeat the test with doors and windows to the premises open and
closed, and with any extractor fans in the same room or adjacent
rooms running on high.
4)
Check that any other open flued appliances and their flues in the
same or adjoining rooms functions correctly when this appliance is
alight.
fig. 22: Spillage test
Smoke match