background image

UK/IRL

 

6

 

<

 

 

3

 

Safety and general information 

 

Before installation, ensure that the local distribution conditions 
(identification of the type of gas and pressure) and the adjustment of 
the appliance are compatible. 

 

This gas appliance is factory set and shall not be adjusted by the 
installer. 

 

This appliance does not contain any component manufactured from 
asbestos or any asbestos related products. 

 

The pilot and flame sensing device fitted to this fire is also a safety 
device. If for any reason any part of the pilot assembly is to be 
replaced the entire assembly including the pilot burner, 
thermocouple, electrode and injector must be exchanged complete 
for a pilot assembly from the original manufacturer only. 

Ventilation 

This appliance is room-sealed and doesn't require purpose provided 
ventilation. 

3.1

 

General safety 

It is the law in the UK that 

all 

gas appliances, are installed by a 

competent person in accordance with the Gas Safety (Installation and 
Use) Regulations (as amended), the relevant British Standards for 
Installation work, Building Regulations, Codes of Practice and the 
manufacturers instructions.  

The installation should also be carried out in accordance with the 
following where relevant:  

 

BS5871 Part1 

 

BS5440 Parts 1 & 2 

 

BS1251. 

 

Building Regulations Document J (as applicable). 

Building Regulations and Standards issued as relevant by the Department 
of the Environment or the Scottish Development Department. 

Summary of Contents for Ease (BF100H)

Page 1: ...F100H SILENCE FEELING SENSE WHISPER SPECTRA NOVA CADRA NOVA Room sealed built in gas fireplace with Flat Fibre Burner Technology Ease also with Pebble burner Installation guide and user manual 40010560 05 11 ...

Page 2: ...UK IRL 2 ...

Page 3: ...5 4 4 Placing the pebble set Ease 26 6 Installation of the flue 27 6 1 Connection with use of concentric duct material 27 6 2 Connection onto an existing chimney 27 6 3 Remote control when applicable 29 6 3 1 Installation 29 7 Commissioning functional checks 31 7 1 Check pilot ignition 31 7 2 Functional burner check 31 7 3 Functional balanced flue check 32 7 4 Check setting pressure 32 8 Handing o...

Page 4: ...UK IRL 4 11 4 2 To extinguish 45 11 4 3 Setting the right transmission code 45 11 4 4 Changing batteries 46 12 Cleaning and service instructions 47 13 Disposal of packaging and appliance 48 ...

Page 5: ... Special features Realistic flame and glow effect because of the Flat Fibre Burner technology Room sealed appliance inlet and outlet are led to the outside using a natural draught concentric pipe system 100 mm 150 mm no power fan required No additional ventilation required Air supply and flue gases go to outside atmosphere through wall or roof A maximum horizontal extension of 6 meters is possible...

Page 6: ...de and injector must be exchanged complete for a pilot assembly from the original manufacturer only Ventilation This appliance is room sealed and doesn t require purpose provided ventilation 3 1 General safety It is the law in the UK that all gas appliances are installed by a competent person in accordance with the Gas Safety Installation and Use Regulations as amended the relevant British Standar...

Page 7: ...with IS813 ICP3 IS327 Building Regulations Codes of Practice the manufacturers instructions and any other rules in force Failure to comply with the above could leave the installer liable to prosecution and invalidate the appliance warranty Safety instructions for the user see chapter 10 ...

Page 8: ...stalled in the following situations In a non combustible fireplace or builders opening This could be either an existing builders opening or a new made prefab builders opening For the measurements see figure 1 and index Although the appliance is tested for installation without a hearth the appliance must not stand on combustible materials or carpets If the appliance is placed on a combustible floor...

Page 9: ...appliance mm F Box width 885 885 885 885 750 750 650 698 G Box depth 369 366 369 366 397 375 375 338 H Box height 605 605 605 605 714 715 815 879 I Frame width 1064 1136 1064 985 815 794 694 740 J Frame height 678 750 678 599 720 703 803 905 K Frame thickness 47 57 20 36 16 30 30 144 L Position flue collar measured from frame 255 255 255 255 257 235 235 196 M Position flue collar measured from bac...

Page 10: ...e area covered by the surround The minimum height from the top surface of the fire to the underside of any shelf made from wood or other combustible materials is as follows For a shelf up to 150 mm deep Minimum height 350 mm fig 1 If the shelf depth is greater than 150 mm add 50 mm to the upper clearance height for every 25 mm increase in shelf depth Side clearance Minimum distance from the side o...

Page 11: ... bend which is in the horizontal area counts for 1 meter à elbows and bends at the transition of horizontal to vertically are not to be counted à the wall mounted terminal counts for 1 meter Flue restrictor If applicable in the table is also stated the size of a flue restrictor This restrictor needs to be fitted in the combustion chamber when placing the appliance see chapter 4 2 Normally the smal...

Page 12: ...xtension fig 2b Flue lenght J L 0 5 0 5 1 m Elbows K M 2m 2m 4 m Terminal 1 m Total horizontal extension 6 m Calculation effective height Hvert Flue lenght H 1 m When calculating on basis of the Widescreen table nr 2 Combination not allowed When calculating on basis of the MV100 table nr 3 Allowed but without flue restrictor Remove the flue restrictor When calculating on basis of the MV150 table n...

Page 13: ...UK IRL 13 an X and when the values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is preinstalled ...

Page 14: ... 60 60 50 X X 9 65 65 60 60 X X X 10 65 65 65 X X X X 11 65 65 X X X X X 12 65 X X X X X X Table 2 Widescreen Ease BF100H Feeling Silence Sense Vertical length in m Table 3 MV100 MV200 Spectra Nova Whisper Horizontal length in m Vertical length in m The numbers in the table represent the width in mm of the flue restrictor X Combination NOT allowed 0 remove flue restrictor The numbers in the table ...

Page 15: ...could come into contact with it then a suitable terminal guard must be fitted Terminals located close to shared walkways footpaths etc could be subject to legal constraints and this should be pointed out to the customer before installation If in any doubt about flue location advice should be sought from local building control or if appliance related from the manufacturer including wherever possibl...

Page 16: ...d terminal has to be at least 0 5 m off à Corners of the building à Below eaves à Balcony s etc unless the duct is dragged to the front side of the overhanging part The roof mounted terminal has to be at a distance of at least 0 5 meters of the sides of the roof excluded the ridge ...

Page 17: ...balconies or cat port roof 600 mm G From a vertical drain pipe or soil pipe 300 mm H Dfrom an internal or external corner 600 mm I Above ground roof or balcony level 300 mm J From a surface facing the terminal 600 mm K From a terminal facing a terminal 600 mm L From an opening in the carport e g window into the dwelling 1200 mm M Vertically from a terminal on the same wall 1500 mm N Horizontally f...

Page 18: ... supply must only service this appliance A chimney that has previously been used for solid fuel must be swept before use The existing chimney needs to be airtight The existing chimney needs to have an opening of min 150 x 150 mm The chimney needs to be intact and well looked after Use the adjustable roof mounted terminal especially made for this and the chimney connection set The min distance betw...

Page 19: ...eter Ensure that the gas pipe does not interfere with the removal or replacement of the burner tray of the controls 5 The gas connection is nut and olive suitable for 8 mm pipe 5 2 Preparing the appliances Before you can install the appliance properly it is wise to prepare the appliance because you still have access to all parts of the appliance These will be barely reachable once the appliance is...

Page 20: ...of the inner frame towards you Push the blocking strips up Lift the inner frame and remove it 3 Remove the back panel by loosening the screws B see fig 7 4 Remove the glass by removing the glass clamps C see fig 8 for instance with a screwdriver Careful when removing the glass Wear gloves Before placing the glass back be sure that there are no Fig 7 Fig 6 ...

Page 21: ...5 Take the box with the log set out of the combustion chamber 6 Place the right flue restrictor in the combustion chamber To determine the right flue restrictor see paragraph 4 2 and 4 3 Attention y If possible first install the appliance before building up the false chimney breast Fig 9 Fig 8 ...

Page 22: ... lift and pull forward Be sure that there are no fingerprints on the glass It is not possible to remove those prints once they are burned in the glass 2 Remove the outer frame by removing screws B see fig 11 and taking away the frame 3 Take the box with the log set out of the combustion chamber 4 Like in the previous models place the right flue restrictor in the combustion chamber see fig 9 To det...

Page 23: ...n extendible pipe before connection onto the appliance 1 Position the firebox in the fireplace opening You can adjust the height with the 4 adjustable feet 2 Make the gas connection according to the instructions also see gas connection chapter 5 1 3 Assemble the flue system onto the firebox see chapter 5 4 Check when applicable if the safety hatch seals the combustion chamber properly Do not faste...

Page 24: ...ance and fix it with the glass clamps Replace the frame Cadra Nova and Spectra Nova Place the door and fix it Check on visual leakages around the door sealing 10 Widescreen Fix the outer frame with 4 screws After installation let the appliance burn for max an hour Afterwards check the glass for possible dirt dust and other deposit and remove it 5 4 Placing the log set Never place extra elements of...

Page 25: ...nd four logs The logs must rest on the log holder and the rear log Ensure that the pilot burner remains visible after installation of the log set When not placing the log set correctly the flames tend to burn to the front against the window 5 4 3 Placing the log set Feeling Silence Sense and Ease The log set consists of two rear logs and six ceramic logs Put the two rear logs on the tray at the ba...

Page 26: ...nt the logs must lay at the holes on the back they rest on the rear logs 5 4 4 Placing the pebble set Ease Spread the pebbles over the bottom of the combustion chamber Make sure that the pilot is not covered or blocked by the pebbles See fig 17 for more details Fig 17 ...

Page 27: ...g down the concentric pipes can turn loose It is recommended to fix the spring clip with a self tapping screw at inaccessible places 7 To get the exact measure flue length you can use cut down concentric pipe wall mounted terminal or roof mounted terminal To obtain a smoke sealed connection the inner pipe must be 20 mm longer then the outside pipe 8 The horizontal pipes need to rise away from the ...

Page 28: ...9 part E and F Installation 1 Place the aluminium closure plate A onto the chimney Permanently attach and make airtight 2 Pull the liner C through the chimney 3 Connect the liner onto the roof terminal and fix this with the clamp provided with the chimney connection set 4 Place the roof terminal onto the closure plate 5 Fixing the chimney sealing plate D and place the 150 mm grommet into the hole ...

Page 29: ... is therefore not possible to ignited the appliance with the remote control or to shut off the pilotflame The radio frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria Denmark Finland and Greece Features Manual control will always remain possible The remote control is a radio frequency type and has been approved internationally The...

Page 30: ...pears if the receiver is disconnected from the mains for a longer period 1 Push the mod button on the receiver and hold it for 3 seconds 2 The green control lamp will light up and stay on Repeat this step if it doesn t 3 Push a button on the remote control The control lamp on the receiver should now go out 4 Again push a button on the remote control The lamp starts flashing and will switch off eve...

Page 31: ...rol knob for a further 10 seconds to ensure that the pilot flame is stable 4 Release the knob The pilot should remain alight If not repeat the previous steps 7 2 Functional burner check 1 Turn knob B to max clockwise 2 Turn knob A more anticlockwise to the position large flame Now it s possible to light the main burner 3 Turn knob B anticlockwise to its max The main burner should light Check for g...

Page 32: ...th the correct side up c If the correct flue restrictor is installed 7 4 Check setting pressure The appliance is preset to give the correct heat input No further adjustment is necessary Fit a pressure gauge at the test point D to check the burner pressure The pressure should be checked with the appliance alight and at max input The setting pressure should be as shown in paragraph 9 4 After checkin...

Page 33: ... to clean the appliance including the glass Instruct the customer on the operation of the remote control including replacement of batteries and how to set the right transmissions code Hand over these instructions including the user guide to the consumer Recommend that the appliance should be serviced by a competent person at least once a year ...

Page 34: ...ers if applicable 3 Do the functional test as described at page 32 4 Check the flue system and terminal on damage and soundness visual inspection 9 1 1 Cleaning the glass Depending on the intensity of use you can get a deposit on the glass This can be removed with a special ceramic glass cleaner ceramic cook top cleaner as follows 1 Remove the front and the back 2 Clean the glass Handle the glass ...

Page 35: ...er If the burner is visibly damaged this can affect the distribution of the flame if so then replace the burner 9 1 3 Burner tray assembly 1 Remove the front glass and log holder if applicable 2 Break the gas supply at the control valve 3 Unscrew the burner assembly and take them out of the combustion 4 chamber Attention A sharp or heavy object can damage the burner A Pilot assembly B Burner C Fix...

Page 36: ...ection to the pilot 4 Unscrew thermocouple nut from the rear of the gas control 5 Unscrew pilot assembly from the burner tray 2 screws 6 Replace and re assemble in reverse order 9 1 5 Gas control block A Govenor B Adjustable screw pilot flame C Inlet pressure test point D Burner pressure test point 9 1 6 Combustion test A BS7967 combustion analysis check should be carried out using an analyser to ...

Page 37: ...05 Log set 20773200 20794500 20794500 20794500 20794500 X 20773200 20794500 Pebble set X X X X X 20799100 X X Spark wire 06017300 06017300 06017300 06017300 06017200 06017200 06017300 06017300 Receiver 20604000 20604000 20604000 20604000 20604000 20604000 20604000 20604000 Remote control 20603900 20603900 20603900 20603900 20603900 20603900 20603900 20603900 Adapter 20900142 20900142 20900142 2090...

Page 38: ...0 10 Injector size mm 2 4 2 55 2 2 2 2 Reduced input restrictor mm 1 8 1 8 1 6 1 6 Pilot Assembly Type Oxy pilot OP9709 Oxy pilot Oxy p Code 9709M NG 9709M NG 9709M Flue system Ø MVr mm 100 150 100 150 100 150 100 Preinstalled flue restrictor mm 30 30 30 30 Gas control Maxitrol GV 36 GV3636 C5AOEHC68M GV3636 C5AOEHC68M GV3636 C5AOEHC68M GV36 C5AOEH Remote control Voltage adapter V 4 5 4 5 4 5 4 5 ...

Page 39: ...UK IRL 39 User Manual ...

Page 40: ...tion to this is the lower side of the door and the control buttons Due to the newness of materials they may give off a slight smell for a period after initial lighting This is normal odours will disperse after a few hours use Do not place curtains clothing laundry furniture or other flammable materials nearby the appliance The required minimum distance is 100 cm Switch off the receiver of the remo...

Page 41: ...ural circulation of air moist and volatile components from paint building materials carpet etc will be attracted These components can settle themselves down onto cold surfaces in the form of soot As on all heat producing appliances soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured This should be born in mind when installing the appli...

Page 42: ...te control only Access to the controls by pulling the inner frame forwards Cadra Nova and Spectra Nova Open by pushing the lip located on the right side in the gap between the ashtray door and the frame door flaps open With control button A you can light the pilot With the control button B you can adjust the height of the flames see fig 26 Knob A The is the OFF position preventing any gas from pas...

Page 43: ... is the OFF position preventing gas entering the main burner if the pilot is lit The knob should be turned slowly anticlockwise This allows gas to enter the burner and be ignited by the pilot flame Once ignition has taken place the fire may be set to any level between min and max by adjusting the control knob B 11 2 To light 1 Push in and turn the control knob A from anticlockwise to the setting s...

Page 44: ... burner is ignited and knob A is in big flame position It is therefore not possible to ignite the pilot flame with the remote control or to extinguish the pilot flame The radio frequency remote control is intended for fireplaces installed in a domestic setting in all EU countries except Austria Denmark Finland and Greece Features Manual control will always remain possible The remote control is a r...

Page 45: ...iod turn off the pilot see 10 4 2 11 4 2 To extinguish 1 Push low till the burner goes out and you can hear the motor clicking 2 To enable the remote control turn knob A to the position 3 To extinguish the pilot turn control knob A to position although it is in order to leave the pilot permanently lit 11 4 3 Setting the right transmission code The receiver has to learn the code from the transmitte...

Page 46: ... the low voltage supply is similar to that used in torches Always turn off the appliance before changing batteries Remote control 1 Remove the cover on the back of the remote control 2 Carefully remove the battery clip along the side Pay attention not to pull the wires 3 If necessary remove the old batteries and place the new ones 2x LR03 Alkaline long life 1 5 V 4 Click the battery clip into the ...

Page 47: ...to cool down before commencing cleaning It is recommended that the fire is inspected serviced by a competent person at least once a year To maintain the finish on the trim wipe with soft damp cloth only Do not use abrasive cleaners polish or solvents as these can damage the surface finish ...

Page 48: ...se materials should be disposed responsibly and in conformity with government regulations Batteries are considered chemical waste The batteries should be disposed of responsibly and in conformity with government regulations Remove the batteries before disposing of the remote control Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities ...

Page 49: ...UK IRL 49 Saturnus 8 NL 8448 CC Heerenveen P O Box 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Reviews: