Installation Instructions
This section describes how to set up your
fi
re.
BEFORE YOU START
1. Ensure that all packing items are removed (read any warning labels carefully) and retain all packing for possible
future use e.g. in the event of moving house or returning the appliance to your supplier.
2. Before connecting to the mains supply, check that the supply voltage is the same as that stated on the appliance.
INSTALLATION
Place the appliance against a wall.
Connecting the Transducer Unit + Lamps
1. Release the two red tabs by turning them by 90 degrees (see Fig 2)
2. Lift out the Sump Nozzle (Fig 3)
3. Insert lamps into lamp holders (Fig 4), carefully locating the pins into the holes (Fig 4a)
4. Push lamps
fi
rmly into place
5. Place the Transducer Unit into the sump and join the cable to the connector on the sump (Fig 5)
6. To ensure that the Transducer Unit is correctly placed in the sump, the tab on the Transducer Unit should be lined
up with the moulded recess in the sump (Fig 5a).
7. Ensure that the cable is not placed above the disc on the Transducer Unit (Fig 5b). To prevent the cable becoming
pinched between the nozzle and the sump, place the cable in the slot in the wall of the sump.
8. Replace the Sump Nozzle and secure it by turning the two red tabs by 90 degrees (Fig 6)
Filling the Water Tank
9. Place Water Tank in sink and remove cap (turn anti-clockwise to open) (Fig 7)
10. Fill Water Tank with
fi
ltered tap water only
. This is necessary to prolong the life of the
fl
ame and smoke effect
producing unit. The water should be
fi
ltered through a conventional domestic water
fi
lter unit and the
fi
lter should be
replaced regularly. Distilled water must
not
be used.
11. Screw the cap back on –
do not overtighten
.
12. Place the Water Tank in the Sump, with the tank cap facing down and the
fl
at side of the tank facing outward (Fig 8)
Assembling the
fi
re
13. Place the Fuelbed on top of the Water Tank and Mist Nozzle (Fig 9)
Connect the power cable to the appropriate power connector at the back of the appliance and
Plug the power cable into a 13amp/240volt outlet. The appliance is now ready for use.
Operating the Fire
This section describes how to activate your
fi
re using either the manual controls or remote control.
MANUAL CONTROLS
The manual controls are located beneath the hinged
fl
ap.
(See Fig.10 for Manual Control lay out)
Switch ‘A’:- Controls the electricity supply to the Fire.
Note: This switch must be in the ‘ON’ (
I
) position for the Fire to operate.
Switch ‘B’:- Press
once to turn on the
fl
ame effect. This will be indicated by an audible beep. Although the main
lights operate immediately it will take a further 30 seconds before the
fl
ame effect starts.
Press to put
fi
re in to standby mode. This will be indicated by one beep.
Control Knob ‘C’:- Controls the intensity of the
fl
ame effect.
Turning the control knob to the left increases the
fl
ame effect, turning the control knob to the right will
decrease the
fl
ame effect.
GETTING THE DESIRED FLAME EFFECT
1. The
fl
ame control knob ‘C’ (Fig.10) may be turned up or down to give a more realistic effect.
2. Generally the
fl
ames appear more realistic when the
fl
ame control is turned down.
3. Give the
fl
ame generator time to react to changes you may make.
4. The appliance will use less water if the
fl
ame effect is set to a lower level (control knob ‘C’).
5. Do not tilt or move the appliance while there is water in the tank or sump.
6. Make sure that the appliance is on a level
fl
oor.
17
Summary of Contents for CAS400
Page 2: ...Fig 1 Fig 4 Fig 4a Fig 2 Fig 3 A mm CAS400 405 CAS600 564 ...
Page 3: ...Fig 5 Fig 5a Fig 5b Fig 6 Fig 7 Fig 8 ...
Page 4: ...Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 ...
Page 5: ...Fig 15 Fig 16 Fig 17 ...
Page 6: ...NL 1 FR 6 DE 11 UK 16 DK 21 ...
Page 32: ......
Page 33: ......
Page 34: ......