3
532096 Rev. B
S800H ENC
T
ranslation of the original instructions
ENGLISH
1) ATTENTION! To ensure the safety of people, it is important that you read
all the following instructions. Incorrect installation or incorrect use of
the product could cause serious harm to people.
2) Carefully read and follow the instructions before beginning to install the
product.
3) Do not leave packing materials (plastic, polystyrene, etc.) within
reach of children as such materials are potential sources of danger.
4) Store these instructions for future reference.
5) This product was designed and built strictly for the use indicated in this
documentation. Any other use, not expressly indicated here, could
compromise the good condition/operation of the product and/or be
a source of danger.
6) FAAC declines all liability caused by improper use or use other than
that for which the automated system was intended.
7) Do not install the equipment in an explosive atmosphere: the presence
of inflammable gas or fumes is a serious danger to safety.
8) The mechanical parts must conform to the provisions of Standards EN
12604 and EN 12605.
For non-EU countries, to obtain an adequate level of safety, the
Standards mentioned above must be observed, in addition to national
legal regulations.
9) FAAC is not responsible for failure to observe Good Technique in
the construction of the closing elements to be motorised, or for any
deformation that may occur during use.
10) The installation must conform to Standards EN 12453 and EN 12445.
For non-EU countries, to obtain an adequate level of safety, the
Standards mentioned above must be observed, in addition to national
legal regulations.
11) Before attempting any job on the system, cut out electrical power .
12) The mains power supply of the automated system must be fitted with
an all-pole switch with contact opening distance of 3mm or greater.
Use of a 6A thermal breaker with all-pole circuit break is recommended.
13) Make sure that a differential switch with threshold of 0.03 A is fitted
upstream of the system.
14) Make sure that the earthing system is perfectly constructed, and
connect metal parts of the means of the closure to it.
15) The automated system is supplied with an intrinsic anti-crushing safety
device consisting of a torque control. Nevertheless, its tripping threshold
must be checked as specified in the Standards indicated at point 10.
16) The safety devices (EN 12978 standard) protect any danger areas
against
mechanical movement Risks
, such as crushing, dragging, and
shearing.
17) Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended
for every system, as well as a warning sign adequately secured to the
frame structure, in addition to the devices mentioned at point “16”.
18) FAAC declines all liability as concerns safety and efficient operation of
the automated system, if system components not produced by FAAC
are used.
19) For maintenance, strictly use original parts by FAAC.
20) Do not in any way modify the components of the automated system.
21) The installer shall supply all information concerning manual operation
of the system in case of an emergency, and shall hand over to the
user the warnings handbook supplied with the product.
22) Do not allow children, things or adults to stay near the product while
it is operating.
23) Keep remote controls or other pulse generators away from children,
to prevent the automated system from being activated involuntarily.
24)
Transit is permitted only when the automated system is idle.
25) The user must not attempt any kind of repair or direct action whatever
and contact qualified personnel only.
26) Maintenance: check at least every 6 months the efficiency of the
system, particularly the efficiency of the safety devices (including,
where foreseen, the operator thrust force) and of the release devices.
27)
The S800H ENC automated system automates vehicle entrances -
pedestrians must have a separate entrance
.
28) Power up the automated system only when expressly indicated.
29) Anything not expressly specified in these instructions is not permitted.
WARNINGS FOR THE INSTALLER
GENERAL SAFETY OBLIGATIONS
AUTOMATED SYSTEM S800H ENC
EC DECLARATION OF CONFORMITY
The Manufacturer
Company name:
FAAC S.p.A.
Address:
Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY
hereby declares that the following products:
Description:
Underground operator for swing leafs gates
Model:
S800H ENC
comply with the following applicable EU legislations:
• EMC Directive 2004/108/EC
• ROHS Directive 2 2011/65/UE
Furthermore, the following harmonised standards have been applied:
• EN EN 60335-2-97:2006
• EN ISO 12100:2010
• EN 61000-6-2:2005
• EN 61000-6-3:2007
Bologna, 22-01-2015
CEO
A. Marcellan
Summary of Contents for S800H ENC
Page 1: ...S800H ENC S800H ENC ...
Page 2: ......
Page 12: ...5 S800H ENC 532096 Rev B www faacgroup com ...
Page 14: ... DEUTSCH FRANÇAIS ITALIANO NEDERLANDS ESPAÑOL ENGLISH ITALIANO FRANÇAIS DEUTSCH ...
Page 19: ......