8  CONNECTION OF TWO R180/280 UNITS

For shutters with a width of over 4.5 meters, we advise installing two R180 
or R280 operators at the sides of the shutter as shown in Fig. 20.

Fig. 21

Fig. 20

Perform the installation procedures of both drive units as explained in 
chapter 3. At the end of the mechanical installation, refer to the following 
procedure:

Remove the service bracket, ref. 

 fig. 11, from both drive units, 

and keep it;

 

When the service bracket has been removed, take 
great care NOT TO MOVE the transmission crowns 
of the operators in order not to compromise the 
positioning of the screws of the travel-limit devices.

Open the cover of both travel-limit units;
Remove the power cable of the SLAVE drive unit and make the 
connections as indicated in figure 21;
Close the cover of both travel-limit units and reposition the service 
brackets.

Continue the installation performing, only for the MASTER operator, the 
instructions given from chapter 5 on page 6.

Therefore the travel-limit devices will be adjusted only on the MASTER unit 
as described in chapters 6 and 6.1.

The electro-brake can be installed independently on the MASTER or 
SLAVE unit.

1.

2.
3.

4.

Assemble the release knob in Figure 18, taking care to fully fasten 
the regulator in ref. 

;

Pull the cable and firmly tighten terminal ref. 

:

- To release the gearmotor, restrain the top of the knob and 

rotate the bottom part clockwise;

- To relock the gearmotor, restrain the top of the knob and rotate 

the bottom part anti-clockwise;

5.

6.

Remove the cover of the travel limit unit, unfastening the three 
visible screws;
Connect the two eyelets coming from the electro-brake to the 
terminal-board of the travel limit unit, as shown in Fig.19 ref.

 

and 

;

Close the cover of the travel limit unit.

7.

8.

9.

Fig. 19

Fig. 18

Summary of Contents for R180

Page 1: ...UTOMATED SYSTEM 4 3 1 PRELIMINARY CHECKS 4 3 2 INSTALLATION DIMENSIONS 4 3 3 INSTALLING THE OPERATOR 4 4 TRAVEL LIMIT UNIT 6 5 ELECTRICAL CONNECTIONS 6 5 1 BUTTON BOARD OR SELECTOR 230 Vac 6 5 2 COMMA...

Page 2: ...ds EN 12453 and EN 12445 For non EU countries to obtain an adequate level of safety the Standards mentioned above must be observed in addition to national legal regulations 11 Before attempting any jo...

Page 3: ...nt temperature 40 C 55 C Shutter Shaft Diameter 60 48 42 mm 60 48 42 mm Winding Flange Diameter 200 220 mm 200 220 mm Maximum Shutter Height 8 m 8 m Maximum Shutter Width 4 5 m 4 5 m Operator Weight 8...

Page 4: ...he shutter shaft removing deposits of dust grease and chips To install two R180 or R280 operators on a shutter having a width of over 4 5 meters please refer to chapter 8 on page 8 Procedure for defin...

Page 5: ...on the winding shaft Insert in the hole you have just drilled the securing screw in Fig 7 ref tightening it to rest on the washer and self locking nut 5 6 If in chapter 1 2 you have measured a windin...

Page 6: ...power supplied by a 230 VAC selector or by control boards 200 BT and 200 MPS To install two R180 280 units on the same winding shaft please refer to chapter 8 on page 8 BEFORE performing the followin...

Page 7: ...ake the shutter into its fully closed position to obtain full access to the travel limit unit 1 As shown in Figure 14 incline downward and keep inclined the rotation constraint lever ref to enable rel...

Page 8: ...1 Close the cover of both travel limit units and reposition the service brackets Continue the installation performing only for the MASTER operator the instructions given from chapter 5 on page 6 There...

Reviews: