21
Std Reverse
Photo Open
Photo Close
GND
GND
Edge Open
Edge Close
24V DC
+
Light Com
Light N.O.
GND
FSW TX
Maglock Com
Maglock N.C.
Solenoid Com
Solenoid N.O.
CLOSE RX
CLOSE TX
OPEN RX
OPEN TX
NO
NC
C
NO
NC
C
Photocell sensor connections
To comply with the UL325 standard monitored safety inputs must be used to protect every entrapment zone. An entrapment zone is
defined as a location or point of contact where a person can be entrapped between the moving gate and a rigid object. The operator
has inputs for entrapment protection photo sensors in the opening and closing direction. These sensors can be monitored for their
presence and correct operation at the beginning of each cycle.
To enable monitoring of the Photocell inputs set Dip Switch 1 OFF. To monitor only the Close input Set Dip Switch 11 OFF, to moni-
tor both Close and Open inputs set Dip Switch 11 ON. When an input is monitored the corresponding photocell must be connected
otherwise the operator will not start. To verify the input is wired properly the corresponding LED must be lit, see figure below.
Photo Close safety input:
The Input is only active during close cycle.
1. An input during the close cycle will stop the gate and reverse it to the full open
position. If the Close Timer option is ON it will be restarted when the input clears.
2. If the Open safety input is active before reaching the full open position, the gate
will stop. When the input is cleared, the gate will continue to reverse open.
Photo Open safety input:
The Input is only active during open cycle.
1. An input during open cycle will stop the gate and initiate a short reverse
2. The gate will remain stopped until the input is cleared.
3. When the input is cleared, the gate will continue to open.
Monitor Photo / Edge
Anti-Tailgate
Master / Slave
Close Timer
Power Fail Open / Cycle
Open Left / Right
Quick Close
Stop (NC / NO)
Low Battery Cycle / Open
Mag / Solenoid Delay
Monitor Close / Op-Cl
Soft Start / Hard Start
Off On
DIP SWITCH 1
DIP SWITCH 11
EC EO PC PO Rev
Std Reverse
Photo Open
Photo Close
GND
GND
Edge Open
Edge Close
24V DC
+
EC EO PC PO Rev
Std Reverse
Photo Open
Photo Close
GND
GND
Edge Open
Edge Close
24V DC
+
Dip Switch 11 - OFF
Dip Switch 11 - ON
NOTE: Dip Switch 1 and 11 change affected inputs to Normally Closed. If there is a fault on the monitored sensor the corresponding
LED will not be lit, or it will not blink at the beginning of each cycle.
Summary of Contents for FSL700
Page 2: ......