22
Edge sensor connections
To comply with UL regulations monitored safety inputs must be used to protect every entrapment zone. An entrapment zone is
defined as a location or point of contact where a person can be entrapped between the moving gate and a rigid object. The operator
has inputs for entrapment protection edge sensors in the opening and closing direction. Use FAAC CN 60 E edge sensor controller
and the schematic below for proper monitoring. The sensors can be monitored for their presence and correct operation at the begin-
ning of each cycle.
To enable monitoring of the the Edge inputs set Dip Switch 1 ON. To monitor only the Close input Set Dip Switch 11 OFF, to monitor
both Close and Open input Set Dip Switch 11 ON. When an input is monitored the corresponding edge controller must be con-
nected otherwise the operator will not start. To verify that the input is wired properly the corresponding LED must be lit, see figure
below.
Edge Close safey input:
Input is only active during close cycle.
1. An input during the close cycle will stop the gate and initiate a short reverse
2. When the edge close input is cleared the gate will remain in a stopped position
until a renewed intended activation input is received (open, close, fire, access,
radio). If the close timer option is ON it will be disabled until a full cycle com-
pletes.
Edge Open safety Input:
Input is only active during open cycle.
1. An input during open cycle will stop the gate and initiate a short reverse
2. When the edge open input is cleared the gate will remain in a stopped position
until a renewed intended activation input is received (open, close, fire, access,
radio).
Std Reverse
Photo Open
Photo Close
GND
GND
Edge Open
Edge Close
24V DC
+
CLOSE EDGE
OPEN EDGE
1
4
7
9
O
N
XS 55
1
4
7
9
O
N
XS 55
CN 60 E
CN 60 E
Light Com
Light N.O.
GND
FSW TX
Maglock Com
Maglock N.C.
Solenoid Com
Solenoid N.O.
Monitor Photo / Edge
Anti-Tailgate
Master / Slave
Close Timer
Power Fail Open / Cycle
Open Left / Right
Quick Close
Stop (NC / NO)
Low Battery Cycle / Open
Mag / Solenoid Delay
Monitor Close / Op-Cl
Soft Start / Hard Start
Off On
DIP SWITCH 1
DIP SWITCH 11
EC EO PC PO Rev
Std Reverse
Photo Open
Photo Close
GND
GND
Edge Open
Edge Close
24V DC
+
EC EO PC PO Rev
Std Reverse
Photo Open
Photo Close
GND
GND
Edge Open
Edge Close
24V DC
+
Dip Switch 11 - OFF
Dip Switch 11 - ON
NOTE: Dip Switch 1 and 11 change affected inputs to Normally Closed. If there is a fault on the monitored sensor the corre
-
sponding LED will not be lit, or it will not blink at the beginning of each cycle.
Summary of Contents for FSL700