Standard Reverse Input:
1. The input is inactive when gate is closed or in the open cycle
2. When the gate is open and Time Delay Close is ON, an input
will reset the Time Delay Close
3. When the gate is open and Time Delay Close is OFF, an input
will prevent the gate from closing
4. When gate is closing, an input will reverse the gate movement
Open, Close, Stop Input:
1. OPEN: An input to this N.O. terminal will start the gate in
the opening direction
2. CLOSE: An input to this N.O. terminal will start the gate in
the closing direction
3. STOP: An input to this N.O. terminal will stop the gate.
If Dip Switch 8 is ON this input will be N.C.
Reset Input:
1. Allows external input to reset gate operator during a Hard
Shutdown.
2. Allows external input to reset operator settings during
installation.
Std Reverse
Photo Open
Photo Close
GND
GND
Edge Open
Edge Close
24V DC
+
Fire
Access
Reset
GND
GND
Stop
Close
Open
OPEN
CLOSE
STOP
Fire
Access
Reset
GND
GND
Stop
Close
Open
RESET
Standard Reverse Connection
The Standard Reverse Terminal can be used to re-open a closing gate. This N.O. input behaves the same as a Reverse Loop. This
connection should not be used for Safety Reverse Devices. Use Edge and Photo inputs for proper Safety connections.
Open, Close, Stop Connections
The Open, Close, Stop Terminals are used to control the gate movement. The controller also has built-in button controls above each
terminal for setup and testing.
External Reset Connection
An external Reset Button may be connected to the Reset Terminal and used to reset the operator during Hard Shutdown situ-
ations. During a Hard Shutdown, the operator can only be reset through the reset input or reset button on the left side of the
controller. The Reset Input can also be used during installation to reset the operator settings.