5.3  

PROGRAMMING

To access the programming menu, the display must indicate the gate 
closed status (

00

).

To access the programming mode from whichever state the gate is in, 
press and release the 

RESET

 button: 

00

 appears on the display.

Press button P1 (

ENTER

), for approximately 5 seconds, until the first 

parameter 

A

 appears.

Press button P2 (

UP/DWN

) to modify the value of the parameter.

Press button P1 (

ENTER

) to go to the next parameter.

After 60 seconds of inactivity, the system will automatically exit from 
the programming menu saving any changes that were made. 
 

parameter default

A

OPEN B input configuration

0

 

partial opening only

1

 

closes only (

CLOSE

)

0

b

Failsafe

0

 not 

enabled

1

 enabled

0

c

Automatic closing

0

 not 

enabled

1

 

enabled, pause 5 s

2

 

enabled, pause 10 s

3

 

enabled, pause 15 s

4

 

enabled, pause 20 s

5

 

enabled, pause 25 s

6

 

enabled, pause 30 s

7

 

enabled, pause 40 s

8

 

enabled, pause 80 s

9

 

enabled, pause 120 s

0

d

OPEN A

 operation

0

 open/stop/close/open...

1

 open/close/open..."

0

E

Partial opening time

0

 3 

s

1

 5 

s

2

 8 

s

3

 10 

s

0

H

Condominium function

0

 

not enabled (the 

OPEN A 

command  is operative during 

opening)

1

 enabled 

(the 

OPEN 

command is ignored during opening)

0

L.

Maximum opening speed

0

 10 

m/min

1

 20 

m/min

2

 30 

m/min

3

 40 

m/min

0

.L

Maximum closing speed

0

 10 

m/min

1

 20 

m/min

2

 30 

m/min

3

 40 

m/min

0

o

Immediate closure after transit across photocells

0

 

not enabled (with automatic closing enabled, the gate always 

closes after the pause time)

1

 

enabled (with automatic closing enabled, the gate closes 

immediately after transit across the closing photocells)

0

parameter default

P

Timer function

0

 not 

enabled

1

 enabled 

(the 

OPEN A

 maintained action control keeps the gate 

open until released)

1

U

Dead-man function

0

 not 

enabled

1

 

enabled (requires the 

OPEN

 A and 

CLOSE

 maintained action 

controls to be used)

 

!

In the dead-man mode:
- The control must be activated intentionally and the 
gate must be visible
- The OPEN input is disabled.
- If the SAFE input is activated during opening or 
closing, it stops the movement immediately.
- If the FSW CL input is activated during closing, it 
stops the movement.
- If the FSW OP input is activated during opening, it 
stops the movement.
- the speed of the gate must be less than 5 m/min

0

Y

Pre-flashing during closing

0

 not 

enabled

1

 1 

s

2

 2 

s

3

 3 

s

4

 4 

s

0

The display, other than when in the programming menu, provides 
information regarding the status of the automation (§ 7.2).

Summary of Contents for E850S

Page 1: ...Kit E850S Translation of the original instructions...

Page 2: ...urs fabricants respectifs Les clients peuvent faire des copies pour leur usage exclusif Ce manuel a t publi en 2017 Copyright FAAC S p A ab dem 2017 Alle Rechte vorbehalten Kein Teil dieses Handbuchs...

Page 3: ...he new frame 10 4 4 Removing the plastic covers 10 4 5 Connections to the board E850S 11 5 START UP 14 5 1 Manual operation 14 5 2 Limit switch adjustment 15 5 3 Programming 17 6 PUTTING INTO SERVICE...

Page 4: ...gns and symbols EN ISO 7010 GENERIC HAZARD Personal injury hazard or risk of damage to components ELECTROCUTION HAZARD Risk of electric shock from live parts CRUSHING HAZARD Risk of crushing of hands...

Page 5: ...mobile guards removed or altered Do not allow water jets of any type or size to come into direct contact with the gearmotor Do not expose the gearmotor to corrosive chemical or atmos pheric agents Do...

Page 6: ...7 LED and accessories power supply terminal board J 8 Cooling fan terminal board JP 1 Connector 5 pin for radio decoder board JP 2 Left opening limit switch connector JP 3 Right opening limit switch...

Page 7: ...Disconnect the power supply and earth wires from the C850 4 1 2 Unscrew the screws of the plastic cover of the E850 board Re move the plastic cover 5 3 DisconnectthelimitswitchcablefromtheE850board Re...

Page 8: ...of the operator 8 9 2 Remove the frame from the base of the operator 10 3 4 DISCONNECT THE LIMIT SWITCHES 1 Unscrew the 2 screws of the limit switch unit cover Remove the cover 11 1 Put the cover and...

Page 9: ...n in 12 2 3 Slide the cable gland seal along the limit switch cable 4 Insert the cable lugs into the cable gland of the limit switch unit 13 5 Connect the cable lugs to the micro limit switches Follow...

Page 10: ...washers included in the Kit 20 21 4 4 REMOVING THE PLASTIC COVERS 1 Unscrew the 7 fixing screws from the plastic covers of the E850S board Remove the plastic covers 22 2 Put the plastic covers and fix...

Page 11: ...ate opens refers to when looking at the gate while standing in front of the C850 26 27 ELECTRIC BRAKE 1 Fasten the electric brake cable to the cable clip on the frame 28 1 2 Make a hole in the cable g...

Page 12: ...ht 230 V max 30 W model to the LAMP terminals of J2 34 COOLING FAN The board cooling fan is connected at the factory to J8 35 The fan is powered by a DC voltage The connection is therefore polarised T...

Page 13: ...which by opening a contact causes the gate to reverse slightly before stopping the automation Active during both opening and closing FSW CL NC contact connect a photocell or another device which by op...

Page 14: ...2 Install the high voltage protection cover on the board E850S and fastenitinplaceusingthe4screwsthatwereputasidepreviously 41 3 Make sure that the C850 has been released 5 1 4 Power up the system 5...

Page 15: ...osing cam 3 closing deceleration cam 4 opening deceleration cam 1 opening cam 2 1 Close the gate as far as the required closed position The closed positionmustbeatleast10cmfromtheexternalmechanicalsto...

Page 16: ...nt 4 Using a screwdriver turn screw number 1 clockwise until the cam engages the micro switch as shown in 52 When the micro switch is activated the LED DL8 R CL turns off 5 Open the gate as far as the...

Page 17: ...bled the OPEN A command is operative during opening 1 enabled the OPEN command is ignored during opening 0 L Maximum opening speed 0 10 m min 1 20 m min 2 30 m min 3 40 m min 0 L Maximum closing speed...

Page 18: ...Ds LED meaning DL5 OP opening limit switch not engaged engaged DL6 OP closing limit switch not engaged engaged DL7 R OP deceleration during opening not engaged engaged DL8 R CL deceleration during clo...

Page 19: ......

Page 20: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 758518 www faac it www faacgroup com Kit E850S 20 532181 Rev A...

Reviews: