background image

Kit  E850S 

532181        -  Rev.A

PE N L

BR

AKE

BR

AKE

L

AMP

L

AMP

OPEN B

OPEN A

SAFE

OPEN

FSW CL

FSW OP

ST

OP 

LOCK

CO

M

-

W.L.
COM

+24V

NC
NO

PE

N

L

U

V

W

W

V

U

MOTOR

OPEN SX

OPEN DX

LIMIT

SWIT

CH  SX

FAN

FAIL SAFE

M

3

OP

R.OP

CL

R.CL

LIMIT

SWIT

CH  DX

ENTER

UP/DWN

RADIO

RESET

T10A

230V~
30W

24V
0.2A

+24V
0.5A max

+

-

2

 

F1

J1

J2

J3

J4

J5

JP1

DISPLAY

P1

P2

J7

J6

JP2

JP3

DL5

DL7

DL6

DL8

J8

P3

DL9

DL10

DL1

1

DL12

DL13

DL14

DL15

Tr

ansla

tion of the original instruc

tions

ENGLISH

BOARD E850S

COMPONENTS

E850S
J 1

Power supply terminal board

J 2

Electric brake and flashing light terminal board

J 3

Left opening motor terminal board 

J 4

Right opening motor terminal board 

J 5

Control devices terminal board

J 6

Failsafe terminal board

J 7

LED and accessories power supply terminal board

J 8

Cooling fan terminal board

JP 1

Connector (5 pin) for radio/decoder board

JP 2

Left opening limit switch connector

JP 3

Right opening limit switch connector

DISPLAY

Programming display

P 1

ENTER

 button

P 2

UP/DWN

 button

P 3

RESET

 button

F 1

Power supply fuse T10A

DL 5

Opening limit switch status LED

DL 6

Closing limit switch status LED

DL 7

Opening deceleration status LED

DL 8

Closing deceleration status LED

DL 9

OPEN 

input status LED

DL 10

OPEN B 

input status LED

DL 11

OPEN A 

input status LED

DL 12

SAFE 

input status LED

DL 13

FSW CL 

input status LED

DL 14

FSW OP 

input status LED

DL 15

STOP 

input status LED

 6 

Board technical data E850S

Power supply voltage

230 V~(+6% -10%)  50/60 Hz

Max power

18 W

Accessories output voltage

24 V 

Max. motor power

1.5 KW

Max. accessories load 

500 mA

Max. flashing light load

30 W (230 V~)

Ambient operating temperature

 -20 °C - +55 °C 

Summary of Contents for E850S

Page 1: ...Kit E850S Translation of the original instructions...

Page 2: ...urs fabricants respectifs Les clients peuvent faire des copies pour leur usage exclusif Ce manuel a t publi en 2017 Copyright FAAC S p A ab dem 2017 Alle Rechte vorbehalten Kein Teil dieses Handbuchs...

Page 3: ...he new frame 10 4 4 Removing the plastic covers 10 4 5 Connections to the board E850S 11 5 START UP 14 5 1 Manual operation 14 5 2 Limit switch adjustment 15 5 3 Programming 17 6 PUTTING INTO SERVICE...

Page 4: ...gns and symbols EN ISO 7010 GENERIC HAZARD Personal injury hazard or risk of damage to components ELECTROCUTION HAZARD Risk of electric shock from live parts CRUSHING HAZARD Risk of crushing of hands...

Page 5: ...mobile guards removed or altered Do not allow water jets of any type or size to come into direct contact with the gearmotor Do not expose the gearmotor to corrosive chemical or atmos pheric agents Do...

Page 6: ...7 LED and accessories power supply terminal board J 8 Cooling fan terminal board JP 1 Connector 5 pin for radio decoder board JP 2 Left opening limit switch connector JP 3 Right opening limit switch...

Page 7: ...Disconnect the power supply and earth wires from the C850 4 1 2 Unscrew the screws of the plastic cover of the E850 board Re move the plastic cover 5 3 DisconnectthelimitswitchcablefromtheE850board Re...

Page 8: ...of the operator 8 9 2 Remove the frame from the base of the operator 10 3 4 DISCONNECT THE LIMIT SWITCHES 1 Unscrew the 2 screws of the limit switch unit cover Remove the cover 11 1 Put the cover and...

Page 9: ...n in 12 2 3 Slide the cable gland seal along the limit switch cable 4 Insert the cable lugs into the cable gland of the limit switch unit 13 5 Connect the cable lugs to the micro limit switches Follow...

Page 10: ...washers included in the Kit 20 21 4 4 REMOVING THE PLASTIC COVERS 1 Unscrew the 7 fixing screws from the plastic covers of the E850S board Remove the plastic covers 22 2 Put the plastic covers and fix...

Page 11: ...ate opens refers to when looking at the gate while standing in front of the C850 26 27 ELECTRIC BRAKE 1 Fasten the electric brake cable to the cable clip on the frame 28 1 2 Make a hole in the cable g...

Page 12: ...ht 230 V max 30 W model to the LAMP terminals of J2 34 COOLING FAN The board cooling fan is connected at the factory to J8 35 The fan is powered by a DC voltage The connection is therefore polarised T...

Page 13: ...which by opening a contact causes the gate to reverse slightly before stopping the automation Active during both opening and closing FSW CL NC contact connect a photocell or another device which by op...

Page 14: ...2 Install the high voltage protection cover on the board E850S and fastenitinplaceusingthe4screwsthatwereputasidepreviously 41 3 Make sure that the C850 has been released 5 1 4 Power up the system 5...

Page 15: ...osing cam 3 closing deceleration cam 4 opening deceleration cam 1 opening cam 2 1 Close the gate as far as the required closed position The closed positionmustbeatleast10cmfromtheexternalmechanicalsto...

Page 16: ...nt 4 Using a screwdriver turn screw number 1 clockwise until the cam engages the micro switch as shown in 52 When the micro switch is activated the LED DL8 R CL turns off 5 Open the gate as far as the...

Page 17: ...bled the OPEN A command is operative during opening 1 enabled the OPEN command is ignored during opening 0 L Maximum opening speed 0 10 m min 1 20 m min 2 30 m min 3 40 m min 0 L Maximum closing speed...

Page 18: ...Ds LED meaning DL5 OP opening limit switch not engaged engaged DL6 OP closing limit switch not engaged engaged DL7 R OP deceleration during opening not engaged engaged DL8 R CL deceleration during clo...

Page 19: ......

Page 20: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 758518 www faac it www faacgroup com Kit E850S 20 532181 Rev A...

Reviews: