background image

E844 3PH 

532315 - Rev.B

Tr

ansla

tion of the orig

inal instruc

tions

ENGLISH

1.  INTRODUCTION TO THIS IN-

STRUCTION MANUAL

EU DECLARATION OF CONFORMITY

The Manufacturer

Company name:

FAAC S.p.A. Soc. Unipersonale

Address:

Via Calari, 10 - 40069 Zola Predosa BOLOGNA 

- ITALY

hereby declares under its own exclusive liability that the fol-

lowing product:

Description:

electronic equipment

Model:

E844 3PH 

complies with the following applicable EU legislations:

2014/30/EU

2014/35/EU

2011/65/UE

Furthermore, the following harmonised standards have been 

applied:

EN 61000-6-2:2005

EN 61000-6-3:2007+A1:2011

EN 60335-1:2012+A11:2014+A13:2017

Other standards applied:

EN 60335-2-103:2015

EN 13849-1:2015 CAT 2 PL “C”

EN 13849-2:2012

Bologna, 01-08-2020

CEO

A. Marcellan

This manual provides the correct procedures and 

requirements for installing E844 3PH and maintaining 

it in a safe condition.

When drafting the manual, the results of the risk 

assessment conducted by FAAC S.p.A. on the entire 

product life cycle have been taken into account in 

order to implement effective risk reduction measures.

The following stages of the life cycle of the product 

have been considered:

 

-

Delivery/handling

 

-

Assembly and installation

 

-

Set-up and commissioning

 

-

Operation

 

-

Maintenance/troubleshooting

 

-

Disposal at the end of the product’s life cycle

Risks arising from installation and using the product 

have been taken into consideration; these include:

 

-

Risks for the installation/maintenance technician 

(technical personnel)

 

-

Risks for the user of the automation system

 

-

Risks to product integrity (damage)

In Europe, the automation of a gate falls under the Ma-

chinery Directive 2006/42/EC and the corresponding 

harmonised standards.  Anyone automating a gate 

(new or existing) is classified as the Manufacturer of the 

Machine.  They are therefore required by law, among 

other things, to carry out a risk analysis of the machine 

(automatic gate in its entirety) and take protective 

measures to fulfil the essential safety requirements 

specified in Annex I of the Machinery Directive.

FAAC S.p.A. recommends that you always comply 

with the EN 12453 standard and in particular that you 

adopt the safety criteria and devices indicated, without 

exception, including the dead-man function.

This manual also contains general information and 

guidelines, which are purely illustrative and not exhau-

stive, in order to facilitate the activities carried out by 

the Manufacturer of the Machine in all respects with 

regard to carrying out the risk analysis and drafting the 

instructions for use and maintenance of the machine. It 

should be clearly understood that FAAC S.p.A. accepts 

no liability for the reliability and/ or completeness of 

the above instructions.  As such, the manufacturer of 

the machine must carry out all the activities required 

by the Machinery Directive and the corresponding 

harmonised standards on the basis of the actual condi-

tion of the locations and structures where the product 

E844 3PH will be installed, prior to commissioning the 

machine. These activities include the analysis of all the 

risks associated with the machine and subsequent 

implementation of all safety measures intended to 

fulfil the essential safety requirements.

Summary of Contents for E844 3PH

Page 1: ...E844 3PH EN FR DE ES NL IT PL TR PT ZH AR RU...

Page 2: ...mi e i marchi citati sono di propriet dei rispettivi fabbricanti I clienti possono effettuare copie per esclusivo utilizzo proprio Questo manuale stato pubblicato nel 2020 Copyright FAAC S p A from 20...

Page 3: ...otor 10 Connecting the earth 10 Mains power supply 10 6 SET UP 11 6 1 Programming 11 6 2 Operating logics 13 6 3 Setup 14 6 4 Restore the default values 14 7 PUTTING INTO SERVICE 14 7 1 Final checks 1...

Page 4: ...an technical personnel Risks for the user of the automation system Risks to product integrity damage InEurope theautomationofagatefallsundertheMa chinery Directive 2006 42 EC and the corresponding har...

Page 5: ...on 1 1 LED off LED on LED flashing LED flashing quickly PERSONAL PROTECTIVE EQUIPMENT Personal protective equipment must be worn to protect against hazards e g crushing cutting shearing etc Obligation...

Page 6: ...t be left within reach of children as they are potential sources of danger Discard the packaging after use in the appropri ate containers in compliance with waste disposal regulations Installation act...

Page 7: ...ch have not been specifically authorised by FAAC S p A ItisprohibitedtousetheE8443PHinthepresence of faults which could compromise safety Do not allow water jets of any type or size to come into direc...

Page 8: ...a size and insulation class that is compliant with current legislation and laid in appropriate rigid or flexible conduits either above or below ground Use separate conduits for the power supply and t...

Page 9: ...4 Removable terminal board for connecting the flash ing light CN5 Terminal board for connecting limit switch CN6 CN11 Quick insertion connectors for inductive limit switch CN8 Removableterminalboardfo...

Page 10: ...etting programming function Sc to connect sensitive edges with NC contact resistive sensitive edges 8 2 k default photocells Reverse after a sensitive edge has been activated can be configured by sett...

Page 11: ...icesconnectedtothe SAFE inputs are working correctly If the test fails the board prevents the automation from moving error 05 To enable disable the failsafe see programming function FS LIMIT SWITCHES...

Page 12: ...range MOTOR CN3 RP DEC MOTOR LAMP 2EASY OPEN SX OPEN DX LIMIT SW F OPEN B OPEN A SAFE CL CL H OP H SAFE OP STOP GND GND OUT 1 OUT 2 TEST OUT 24V U V W M 3 LAMP N GND 24V FCC FCA 230V 60W max 1500 W ma...

Page 13: ...impact forces to fall within the limits indicated in the standard 6 CarryoutthelearningprocedureforanyBUS2easy devices function bU in programming 7 Set the functions So safety in opening and Sc safet...

Page 14: ...44 R 3PH Y enabled no not enabled Y rP Pre limit switch deceleration as a percentage of the travel of the gate that wasmemorisedduringlearningprocedurefor the work times available only for 844 R 3PH 0...

Page 15: ...herstates it has the same function as the OPEN A command In logics B and C separate opening and closing com mand logics OPEN B only closes the gate A AUTOMATIC ThislogiconlyrequirestheOPENcommandtobeu...

Page 16: ...acteristics of the gate change Set up procedure The gate MUST engage the CLOSED limit switch make sure that the FCC LED is off Select the tl function in programming Press and hold down the and buttons...

Page 17: ...ing function FS 8 2 SENSITIVE EDGES If the sensitive edge is used to protect against a hazard it must comply with standard EN 12978 The E844 3PH board has two inputs for connecting sensitive edges tha...

Page 18: ...air of photocells must have the same DIP switch settings There must never be two or more pairs of photocells with the same DIP switch settings If there is more than one pair of photocells with the sam...

Page 19: ...Open B_3 1 0 0 1 0 Open B_1 1 0 0 1 1 Open A_3 Open B_4 1 0 1 0 0 Open B_2 1 0 1 0 1 Open A_3 StopNC_1 1 0 1 1 0 Open B_3 1 0 1 1 1 Open A_3 Close 1 1 0 0 0 Open B_4 1 1 0 0 1 Open A_4 Open B_3 1 1 0...

Page 20: ...positionandno connected device active on off 6 Alarms Errors display meaning AL 27 obstacle detected Er 05 failsafe test failed Er 15 motion timeout 7 Status of the LEDs LED meaning STOP Stop command...

Page 21: ...that the safety edges operate correctly when faced with an obstacle 6 Check that each pair of photocells is working correctly 6 Checkthatthereisnooptical lightinterferencebetweenthe pairs of photocel...

Page 22: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 09 57 820 www faac it www faacgroup com E844 3PH 20 532315 Rev B...

Reviews: