E844 3PH 18
532315 - Rev.B
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
5
Automated system status
display
meaning
00
gate closed
01
gate open
03
gate stopped
04
gate stopped in pause
05
gate opening
06
gate closing
09
gate pre-flashing, then opens
10
gate pre-flashing, then closes
CHECKING BUS 2EASY DEVICES
1. Select parameter
bu
in basic programming. If
there are no devices registered,
no
will appear on
the display, otherwise segment 13 will be lit (
).
This menu can be used to check the operation of
the registered devices: activate each device and
check that the corresponding segment lights up
).
2. Press and hold the
++
button and keep it pressed;
the segments relative to the registered devices
will come on. Each segment of the display cor-
responds to a type of device:
9. DIAGNOSTICS
9.1 FIRMWARE VERSION
The firmware version is show on the display for one
second each time it is switched on.
9.2 AUTOMATED SYSTEM STATUS
The display, other than when in the programming
menu, provides information regarding the status of
the automation system (
).
9.3 ALARMS/ERRORS
indicates the meaning of the relative codes.
9.4 LEDS CHECK
bold indicates the condition of the LEDs with the
board powered, the gate at its halfway position and no
connected device active (
=on ;
=off).
6
Alarms/Errors
display
meaning
AL 27
obstacle detected
Er 05
failsafe test failed
Er 15
motion timeout
7
Status of the LEDs
LED
meaning
STOP
Stop command
not active
active
CL - H
Priority close command
active
not active
OP - H
Priority open command
active
not active
SAFE CL
Closing safety device
not active
active
SAFE OP
Opening safety device
not active
active
OPEN B
Partial motion command
active
not active
OPEN A
Total motion command
active
not active
FCA
Opening limit switch
not engaged
engaged
FCC
Closing limit switch
not engaged
engaged
BUS
Bus 2easy devices
See § BUS 2easy devices
BUS MON
Bus 2easy line
1
12
RP/DEC
MO
TOR
LAM
P
M
AINS
2EASY
OPEN SX OPEN DX
LIMIT SW
F
-
+
OPEN B
OPEN A
SAFE CL
CL -H
OP-H
SAFE OP
STOP
GND
GND
OUT 1
OUT 2
TEST OUT
+24V
N
L1
U
V
W
L2
L3
M
3
LAMP
N
GND
+24V
FCC
FC
A
230V~
60W max
1500 W max
1
2
3
4
5
6
7
8
9
10
11
12
13
400V~ 3PH + N
INPUT
2
11
3
10
4
9
7
14
6
RP/DEC
MO
TOR
LAM
P
M
AINS
2EASY
OPEN SX OPEN DX
LIMIT SW
F
-
+
OPEN B
OPEN A
SAFE CL
CL -H
OP-H
SAFE OP
STOP
GND
GND
OUT 1
OUT 2
TEST OUT
+24V
N
L1
U
V
W
L2
L3
M
3
LAMP
N
GND
+24V
FCC
FC
A
230V~
60W max
1500 W max
1
2
3
4
5
6
7
8
9
10
11
12
13
400V~ 3PH + N
INPUT
5
8
13
1
Open A control device
2
Open B control device
3
Closing photocells
4
Photocells for Open impulse
5
Opening/closing photocells
6
Close control device
7
Opening photocells
8
Stop control device
9
Closing sensitive edge
10
Not used
11
Not used
12
Opening sensitive edge
13
BUS 2easy status
14
Not used
5