6.  SET-UP

RISKS

PERSONAL PROTECTIVE EQUIPMENT

 

!

During operation, there is a risk of fingers and 

hands being trapped between the rack, pinion and 

gearmotor.

Carry out the steps, referring to the relative sections 

for details.

1.  Turn power on to the board and use the diagnostics 

to check the status of the connections.

2.  Check the direction of rotation of the motor:

 

-

release the gearmotor, move the gate manually to 

its half-travel position and then re-lock it

 

-

activate the open command OP-H temporarily 

and make sure that the gate moves in the open-

ing direction

 

-

if the gate moves in the closing direction, tempo-

rarily disconnect the power supply and invert two 

phases of the motor (on connector CN3)  

3.  Release the gearmotor, move the gate manually to 

its closed position and then re-lock it (

make sure 

that the FCC led switches off in this position and 

that 

00

) appears on the display.

4.  Set the type of gearmotor connected: function 

dF

 

in programming. 

5.  Only for 844 R 3PH: program the pre-limit switch 

decelerations in function 

rP

 in programming.  The 

pre-limit switch deceleration reduces the inertia of 

the gate, allowing the impact forces to fall within 

the limits indicated in the standard.

6.  Carry out the learning procedure for any BUS 2easy 

devices: function 

bU

 in programming.

7.  Set the functions 

So

  (safety in opening) and 

Sc

 

(safety in closing) according to the type of devices 

connected.

8.  Carry out the learning procedure for the work times 

(SETUP): function 

tL

 in programming.

 

i

In order for the SETUP procedure to be carried out, 

the CLOSED limit switch must be engaged by the gate.

9.  If the board is installed on gearmotor 844 R 3PH, 

regulate the obstacle detection sensitivity: func-

tion 

EC

 in programming.

10. Complete the programming according to the 

required operating characteristics.

11. Make sure that the automation system is working 

properly with all the devices installed.

6.1  PROGRAMMING

 

Accessing the programming menu

 

-

Press and hold button 

F

: the first function 

dF

 ap-

pears on the display.  The function is displayed as 

long as the 

F

 button remains pressed.

 

-

Release button 

F

: the display shows the value of 

the function.

 

Modifying the settings

 

-

When the display indicates the value of the func-

tion, press the 

+

 or 

-

 button to modify it.

 

-

Press button 

F

 to go to the next function. The 

function is displayed as long as button F remains 

pressed.

 

i

The changes are saved when you exit from program-

ming mode.

 

Exiting programming mode

 

-

 Scroll through the menu until you reach the 

St

 

function and release the button. The display reverts 

to the automation status view.  Alternatively, 

press buttons 

F

 and 

-

 simultaneously at any time 

during programming.

Summary of Contents for E844 3PH

Page 1: ...E844 3PH EN FR DE ES NL IT PL TR PT ZH AR RU...

Page 2: ...mi e i marchi citati sono di propriet dei rispettivi fabbricanti I clienti possono effettuare copie per esclusivo utilizzo proprio Questo manuale stato pubblicato nel 2020 Copyright FAAC S p A from 20...

Page 3: ...otor 10 Connecting the earth 10 Mains power supply 10 6 SET UP 11 6 1 Programming 11 6 2 Operating logics 13 6 3 Setup 14 6 4 Restore the default values 14 7 PUTTING INTO SERVICE 14 7 1 Final checks 1...

Page 4: ...an technical personnel Risks for the user of the automation system Risks to product integrity damage InEurope theautomationofagatefallsundertheMa chinery Directive 2006 42 EC and the corresponding har...

Page 5: ...on 1 1 LED off LED on LED flashing LED flashing quickly PERSONAL PROTECTIVE EQUIPMENT Personal protective equipment must be worn to protect against hazards e g crushing cutting shearing etc Obligation...

Page 6: ...t be left within reach of children as they are potential sources of danger Discard the packaging after use in the appropri ate containers in compliance with waste disposal regulations Installation act...

Page 7: ...ch have not been specifically authorised by FAAC S p A ItisprohibitedtousetheE8443PHinthepresence of faults which could compromise safety Do not allow water jets of any type or size to come into direc...

Page 8: ...a size and insulation class that is compliant with current legislation and laid in appropriate rigid or flexible conduits either above or below ground Use separate conduits for the power supply and t...

Page 9: ...4 Removable terminal board for connecting the flash ing light CN5 Terminal board for connecting limit switch CN6 CN11 Quick insertion connectors for inductive limit switch CN8 Removableterminalboardfo...

Page 10: ...etting programming function Sc to connect sensitive edges with NC contact resistive sensitive edges 8 2 k default photocells Reverse after a sensitive edge has been activated can be configured by sett...

Page 11: ...icesconnectedtothe SAFE inputs are working correctly If the test fails the board prevents the automation from moving error 05 To enable disable the failsafe see programming function FS LIMIT SWITCHES...

Page 12: ...range MOTOR CN3 RP DEC MOTOR LAMP 2EASY OPEN SX OPEN DX LIMIT SW F OPEN B OPEN A SAFE CL CL H OP H SAFE OP STOP GND GND OUT 1 OUT 2 TEST OUT 24V U V W M 3 LAMP N GND 24V FCC FCA 230V 60W max 1500 W ma...

Page 13: ...impact forces to fall within the limits indicated in the standard 6 CarryoutthelearningprocedureforanyBUS2easy devices function bU in programming 7 Set the functions So safety in opening and Sc safet...

Page 14: ...44 R 3PH Y enabled no not enabled Y rP Pre limit switch deceleration as a percentage of the travel of the gate that wasmemorisedduringlearningprocedurefor the work times available only for 844 R 3PH 0...

Page 15: ...herstates it has the same function as the OPEN A command In logics B and C separate opening and closing com mand logics OPEN B only closes the gate A AUTOMATIC ThislogiconlyrequirestheOPENcommandtobeu...

Page 16: ...acteristics of the gate change Set up procedure The gate MUST engage the CLOSED limit switch make sure that the FCC LED is off Select the tl function in programming Press and hold down the and buttons...

Page 17: ...ing function FS 8 2 SENSITIVE EDGES If the sensitive edge is used to protect against a hazard it must comply with standard EN 12978 The E844 3PH board has two inputs for connecting sensitive edges tha...

Page 18: ...air of photocells must have the same DIP switch settings There must never be two or more pairs of photocells with the same DIP switch settings If there is more than one pair of photocells with the sam...

Page 19: ...Open B_3 1 0 0 1 0 Open B_1 1 0 0 1 1 Open A_3 Open B_4 1 0 1 0 0 Open B_2 1 0 1 0 1 Open A_3 StopNC_1 1 0 1 1 0 Open B_3 1 0 1 1 1 Open A_3 Close 1 1 0 0 0 Open B_4 1 1 0 0 1 Open A_4 Open B_3 1 1 0...

Page 20: ...positionandno connected device active on off 6 Alarms Errors display meaning AL 27 obstacle detected Er 05 failsafe test failed Er 15 motion timeout 7 Status of the LEDs LED meaning STOP Stop command...

Page 21: ...that the safety edges operate correctly when faced with an obstacle 6 Check that each pair of photocells is working correctly 6 Checkthatthereisnooptical lightinterferencebetweenthe pairs of photocel...

Page 22: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 09 57 820 www faac it www faacgroup com E844 3PH 20 532315 Rev B...

Reviews: