8
ENGLISH
FO
MOTOR POWER:
Adjusts the motor power level
01
= minimum power
50
= maximum power
When the power value has been changed, it is advisable to perform a new
SETUP (see par. 7.3)
50
So
OPENING SPEED:
Adjusts the motor opening speed to 10 levels
0 1
= minimum speed
1 0
= maximum speed
When the speed value has been changed, it is advisable to perform a new
SETUP (see par. 7.3)
08
Sc
CLOSING SPEED:
Adjusts the motor closing speed to 10 levels.
0 1
= minimum speed
1 0
= maximum speed
When the speed value has been changed, it is advisable to perform a new
SETUP (see par. 7.3)
08
ro
SLOWING DURING OPENING
Adjusts the slowing space as a percentage of the total gate travel. Adjustable from
5
(with
speed <5),
10
(with speed between 5 and 8),
15
(with speed >8) to
99
% in 1% steps.
5-10-15
= minimum slowing
99
= maximum slowing
20
rc
SLOWING DURING CLOSING:
Adjusts the slowing space as a percentage of the total gate travel. Adjustable from
5
(with
speed <5),
10
(with speed between 5 and 8),
15
(with speed >8) to
99
% in 1% steps.
5-10-15
= minimum slowing
99
= maximum slowing
20
Sr
SPEED DURING SLOWING:
Adjusts gate speed during slowing.
0
= LOW speed
1
= HIGH speed
0
St
STATUS OF AUTOMATED SYSTEM:
Exit from programming, data storage, and return to gate status display.
00
= CLOSED
01
= OPEN
02
= Stop then “OPEN”
03
= Stop then “CLOSE”
04
= In “PAUSE”
05
= During opening stage
06
= During closing stage
07
= FAIL SAFE in progress
08
= BUS-2EASY device check in progress
09
= Preflashing then “OPEN”
10
= Preflashing then “CLOSE”
11
= OPEN in Partial Opening
12
= in PAUSE Partial Opening
Display
Function
Default
1