9
ENGLISH
5.2 2
nd
LEVEL PROGRAMMING
To access 2ND LEVEL PROGRAMMING, press push-button
F
and hold down while pressing push-button
+
:
if you also release push-button
F
, the display shows the value of the function that can be modified with keys
+
and
-
.
if you press key
F
(and hold down), the display shows the name of the next function. If you release it, the value
that can be modified with keys
+
and
-
is displayed.
when you reach the last function, press
F
to exit programming, and the display resumes showing the automated
system status.
•
•
•
2
nd
LEVEL PROGRAMMING
Display
Function
Default
1
bo
MAXIMUM TAKE-OFF POWER:
The motor works at maximum power (ignoring the selected power level) during the move-
ment take-off.
Y
= active
no
= excluded
no
PF
PREFLASHING:
Allows 5 types of preflashing to be selected, with a duration equal to 3 secs.
no
= no preflashing
.
OC
=preflashing before each movement.
CL
= preflashing before a closing movement.
OP
= preflashing before an opening movement.
PA
= preflashing only at end of pause.
no
tP
PREFLASHING TIME (visible only if preflashing is selected in the previous menu):
Adjusts preflashing time from
1
to
10
sec. in 1 second steps.
01
= minimum preflashing
10
= maximum preflashing
03
Ph
CLOSING PHOTOCELLS:
Activate the function if you want the closing photocells to lock movement and reverse it on
disengagement. Normally, operation of the closing photocells immediately puts the gate
into reverse when this function is off.
Y
= reversal on disengagement
no
= immediate reversal to opening
no
oP
OPENING PHOTOCELLS:
Activate the function if you want the opening photocells to lock movement and reverse it
during closing. Normally, with this function off, operation of the opening photocells determines
the resumption of movement on their disengagement.
n o
= immediate reversal to closing
no
= resumption of motion on disengagement
no
Ad
ADMAP FUNCTION
Permits activation of operation in accordance with French standard NFP 25/362.
Y
= active
no
= excluded
no
EC
ENCODER:
The "virtual" encoder on the board operates as an anti-crushing device and manages the
slowing and partial opening start points.
If the gate strikes an obstacle during the opening or closing stage, the "virtual" encoder causes
reversal of the motion. The second obstacle detected in the same direction causes the motor
to stop. An alarm is signalled in both cases (see section on alarms).
It is necessary to adjust the sensitivity of the "virtual" encoder by varying the time that the
board waits for before controlling reversal of motion from a minimum of
0
sec to a maximum
of
10
sec in one-second steps.
00
= maximum sensitivity
10
= minimum sensitivity
02