8
Tab. 5
Tab. 6
ENGLISH
11 LOGIC TABLES
LOGIC “
A
” (2)
PULSES
ST
A
TUS OF AUTOMA
TED
SYSTEM
OPEN A
OPEN B
STOP
FSW
-O
P
FSW
-C
L
FSW
-OP/CL
FSW
-OPEN
CL
OSED
opens leaves and
closes after pause
time
opens leaf 1 and
closes after pause
time
no effect (opening
inhibited)
no effect (opening
inhibited)
no effect
no effect (opening
inhibited)
opens leaves and
closes after pause
time
OPENING
no effect (1)
no effect
stops operation
reverses immediately
at closing
no effect
stops and continues
to open at
disengagement
no effect (1)
OPEN IN P
AUSE
recharge
the pause time (1)
recharge
the pause time
stops operation
no effect
recharges pause
time
(closing inhibited)
recharges pause
time
(closing inhibited)
recharges pause
time
(closing inhibited) (1)
CL
OSING
reverses immediately
at opening
reverses immediately
at opening
stops operation
no effect
reverses immediately
at opening
stops and
, at
disengagement
,
reverses at opening
reverses immediately
at opening
STOPPED
closes
closes
no effect (opening
and closing inhibited)
no effect (opening
inhibited)
no effect (closing
inhibited)
no effect (opening
and closing inhibited)
opens leaves
LOGIC “EP
”
PULSES
ST
A
TUS OF AUTOMA
TED
SYSTEM
OPEN A
OPEN B
STOP
FSW
-O
P
FSW
-C
L
FSW
-OP/CL
FSW
-OPEN
CL
OSED
opens leaves
opens leaf 1
no effect (opening
inhibited)
no effect (opening
inhibited)
no effect
no effect (opening
inhibited)
opens leaves
OPENING
stops operation (1)
stops operation
stops operation
reverses immediately
at closing
no effect
stops and continues
to open at
disengagement
no effect (1)
OPEN
closes
closes
no effect (closing
inhibited)
no effect
no effect (closing
inhibited)
no effect (closing
inhibited)
no effect (1)
CL
OSING
stops operation
stops operation
stops operation
no effect
reverses immediately
at opening
stops and
, at
disengagement
,
reverses at opening
reverses immediately
at opening
STOPPED
After OPEN
: R
estarts moving in reverse
direction
After ST
OP
: R
e-closes the leaf/ves
immediately (1)
no effect (opening
and closing inhibited)
no effect (opening
inhibited)
no effect (closing
inhibited)
no effect (opening
and closing inhibited)
opens leaves
(1) If the cycle began with OPEN-B (par
tial opening), an OPEN-
A pulse will activate both leaves to open.
(2) The automatic logic A is equipped with the “
Timer
” function
. This function mak
es it possible to k
eep the gate open with a t
imed OPEN command
. On release of this com
-
mand
, the gate is automatically closed at the end of the set pause time
. If the OPEN B command is used as a timed contact
, when
an OPEN A command is sent
, the
board per
forms a total opening and at the end of the pause time it closes only leaf 2.