![background image](http://html1.mh-extra.com/html/faac/e024s/e024s_manual_3112571006.webp)
6.3
TIME - SETUP LEARNING
Before any manoeuvre is executed, a SETUP
cycle must first be run.
If the motor type is changed with the DS3 and
DS4 dip-switches after the SETUP, a new SETUP
is requested.
When the board is powered up and a SETUP cycle has never
been executed, LEDs LD4 and LD5 begin to flash slowly to signal
that a SETUP cycle must be executed.
There are two possible types of SETUP: AUTOMATIC and
MANUAL
LED
ON (closed contact)
OFF (open contact)
STOP
Command disabled
Command enabled
OPEN A
Command enabled
Command disabled
OPEN B
Command enabled
Command disabled
BUS
See par. 7.2
6
START-UP
6.1
LEDS CHECK
The following table shows that status of the LEDs in relation to
the status of the inputs (the closed at rest automated system
condition is shown in bold).
Check the status of the signalling LEDs as per table below:
Tab.1 – Operation of inputs status LEDs
6.2
PROGRAMMING THE DIPS-SWITCH
The settings of the DS1 dip-switch for programming the force
and the type of motor are shown in the following table.
Tab. 2 - DS programming
(default settings in bold)
(*) If DS3-DS4 are set to ON, during the setup
phase the EncS700 or EncS450 encoder auto-
matically recognizes the S700H or S450H con-
nected operator.
Before performing the Setup, select the opera-
tor connected to the E024S equipment with the
DS1(DS3-DS4) DIP switches.
6.2.1 PRELIMINARY PHASE OF AUTOMATIC OR MANUAL SETUP
The Automatic or Manual SETUP phase is preceded by an initiali-
sation phase: by pressing the SETUP push-button for automatic
or manual setup, the leaves open, one at a time and from any
position, until an obstacle or an Open impulse is detected. Then
the leaves start closing, one at a time, until an obstacle or an
Open impulse is detected. Then the procedure described in
paragraph 6.3.1 or paragraph 6.3.2 starts.
At the end of a successful SETUP procedure the LEDs switch
off.
Otherwise, the procedure ends with the request of a new SETUP
signaled by blinking LEDs.
6.3.1 AUTOMATIC SETUP
To enter in Automatic setup, press the SETUP push-button until
the two LD4 and LD5 LEDs are permanently lit. Then release
the SETUP push-button.
During the Setup phase both LEDs blink.
The Setup phase is preceded by a preliminary phase,
6.2.1.
Then the leaves start moving, one at a time, from the closed
position.
Once an opening stop or an "open" impulse is detected,
they reach the open position and the setup is ended.
Slow-downs can not be set.
The pause time is fixed at 30 s.
Once the SETUP procedure is started, switch
the motor supply cables if the leaves close
instead of opening.
With the AUTOMATIC SETUP, the slow-down
spaces, the closing leaf delays and the pause
time (30 s, with A logic) are defined during
the Setup phase. To change the opening/clos-
ing leaf delay and the pause time, use the
second level menu.
1.
6.3.2 MANUAL SETUP
To enter in Manual setup, press the SETUP push-button until the
two LD4 and LD5 LEDs are permanently lit. Keep it pressed until
the automated system starts moving automatically.
During the Setup phase both LEDs blink.
The Setup phase is preceded by a preliminary phase,
6.2.1.
Then the leaves start moving, one at a time, from the closed
position with an "open" command or automatically.
Open impulse ---> slowdown from leaf opening 1. If a
stop is detected, an opening stop search is set. If Open is
detected, a stop in the stored open position is set.
Starting from leaf opening 2.
1.
2.
DS4
DS3
DS2
DS Description
OFF
OFF
MOTOR 39
ON
OFF
MOTOR 418
OFF
ON
MOTOR 413-415-390-770
ON
ON
HYDRAULIC MOTOR (*) S450H
/ S700H
OFF
OFF LOW FORCE
ON
OFF MEDIUM - LOW FORCE
OFF
ON
MEDIUM - HIGH FORCE
ON
ON
HIGH FORCE
ENGLISH
5
Summary of Contents for E024S