TIME - SETUP LEARNING

 Before  any  manoeuvre  is  executed,  a  SETUP 

cycle must first be run.

 If the motor type is changed with the DS3 and 

DS4 dip-switches after the SETUP, a new SETUP 
is requested.

When the board is powered up and a SETUP cycle has never 
been executed, LEDs LD4 and LD5 begin to flash slowly to signal 
that a SETUP cycle must be executed.
There  are  two  possible  types  of  SETUP:  AUTOMATIC  and 
MANUAL

LED

ON (closed contact)

OFF (open contact)

STOP

Command disabled

Command enabled

OPEN A

Command enabled

Command disabled

OPEN B

Command enabled

Command disabled

BUS

See par. 7.2

 6 

START-UP

6.1 

 LEDS CHECK

The following table shows that status of the LEDs in relation to 
the status of the inputs (the closed at rest automated system 
condition is shown in bold).
Check the status of the signalling LEDs as per table below:

Tab.1 – Operation of inputs status LEDs

6.2 

PROGRAMMING THE DIPS-SWITCH

The settings of the DS1 dip-switch for programming the force 
and the type of motor are shown in the following table.

                                                 Tab. 2 - DS programming 
                                                    (default settings in bold)

 (*) If DS3-DS4 are set to ON, during the setup 

phase the EncS700 or EncS450 encoder auto-

matically recognizes the S700H or S450H con-

nected operator. 

 Before performing the Setup, select the opera-

tor connected to the E024S equipment with the 

DS1(DS3-DS4) DIP switches.

 6.2.1 PRELIMINARY PHASE OF AUTOMATIC OR MANUAL SETUP

The Automatic or Manual SETUP phase is preceded by an initiali-
sation phase: by pressing the SETUP push-button for automatic 
or manual setup, the leaves open, one at a time and from any 
position, until an obstacle or an Open impulse is detected. Then 
the leaves start closing, one at a time, until an obstacle or an 
Open impulse is detected. Then the procedure described in 
paragraph 6.3.1 or paragraph 6.3.2 starts.
At the end of a successful SETUP procedure the LEDs switch 
off.
Otherwise, the procedure ends with the request of a new SETUP 
signaled by blinking LEDs.

6.3.1  AUTOMATIC SETUP

To enter in Automatic setup, press the SETUP push-button until 
the two LD4 and LD5 LEDs are permanently lit. Then release 
the SETUP push-button. 
During the Setup phase both LEDs blink.

The  Setup  phase  is  preceded  by  a  preliminary  phase, 
6.2.1.

Then the leaves start moving, one at a time, from the closed 
position.

Once an opening stop or an "open" impulse is detected, 
they reach the open position and the setup is ended. 

 Slow-downs can not be set.
 The pause time is fixed at 30 s.

 

 

Once the SETUP procedure is started, switch 

the motor supply cables if the leaves close 

instead of opening.

 

With  the  AUTOMATIC  SETUP,  the  slow-down 

spaces, the closing leaf delays and the pause 

time (30 s, with A logic) are defined during 

the Setup phase. To change the opening/clos-

ing leaf delay and the pause time, use the 

second level menu.

1.

 

6.3.2  MANUAL SETUP

To enter in Manual setup, press the SETUP push-button until the 
two LD4 and LD5 LEDs are permanently lit. Keep it pressed until 
the automated system starts moving automatically.
During the Setup phase both LEDs blink.

The  Setup  phase  is  preceded  by  a  preliminary  phase, 
6.2.1.

Then the leaves start moving, one at a time, from the closed 
position with an "open" command or automatically.

Open  impulse  --->  slowdown  from  leaf  opening  1.  If  a 
stop is detected, an opening stop search is set. If Open is 
detected, a stop in the stored open position is set.
Starting from leaf opening 2.

1.

2.

DS4

DS3

DS2

DS Description

OFF

OFF

MOTOR 39

ON

OFF

MOTOR 418

OFF

ON

MOTOR 413-415-390-770

ON

ON

HYDRAULIC MOTOR (*) S450H 
/ S700H

OFF

OFF LOW FORCE

ON

OFF MEDIUM - LOW FORCE

OFF

ON

MEDIUM - HIGH FORCE

ON

ON

HIGH FORCE  

ENGLISH

5

Summary of Contents for E024S

Page 1: ...E024S...

Page 2: ...underwent a test in a typical uniform configuration all products made by FAAC S p A Bologna 01 03 2009 The Managing Director A Marcellan INDEX 0 BOX LAYOUT 2 1 WARNINGS 3 2 LAYOUT AND CONNECTIONS 3 3...

Page 3: ...n Fig A The lid hinges can be moved upward to allow opening the box housing Fig C they can also be removed and re positioned in order to enable the lid to open to the right or left When you have secur...

Page 4: ...ing threshold Always separate power cables from control and safety cables push button receiver photocells etc To avoid any electrical disturbance use separate sheaths or a screened cable with the scre...

Page 5: ...2 GND Negative 3 STOP Device with NC contact which causes the automated system to shut down 4 OPEN B Device with N O contact see chap FUNCTION LOGICS 5 OPEN A J10 RED terminal BUS Safety devices with...

Page 6: ...en impulse is detected Then the procedure described in paragraph 6 3 1 or paragraph 6 3 2 starts At the end of a successful SETUP procedure the LEDs switch off Otherwise the procedure ends with the re...

Page 7: ...E LOGIC Repeatedly press the SW3 push button to select one of the 7 programming logics available The selected logic is signaled by the LD7 LED The number of blinkings corresponds to the number of the...

Page 8: ...CLOSING ON OFF OFF ON ON OFF ON OFF ON OFF ON ON ON ON OFF OFF ON ON OFF ON ON ON ON OFF OFF ON OFF OFF A OPENING and CLOSING OFF ON OFF ON ON ON ON ON OPEN PULSE Tab 3 Addressing of BUS Photocells T...

Page 9: ...EN A or partial opening OPEN B and as you hold it down also press the SETUP SW1 push button The relevant LED starts to flash slowly for 5 sec Release both push buttons Within these 5 sec while the rad...

Page 10: ...e controls only with receiver module at 433 MHz Press the LOGIC SW3 or SPEED SW2 push button to memory store respectively total opening OPEN A or partial opening OPEN B and as you hold it down also pr...

Page 11: ...tion to the indications of the status LEDs on the body of each encoder Fig 1 Below we list the functions of LEDs LD1 DL2 and DL3 and their statuses TAB 1 Encoder connection and LED status LED LIGHTED...

Page 12: ...release OPEN stops saves CLOSE OPEN rerecloses leaves immediately 1 rerecloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disabled CLOSING...

Page 13: ...d opens at release saves CLOSE OPEN IN PAUSE restores pause time 1 restores pause time 1 stops operation no effect locks and closes on disengage ment after 5 s recharges pause time CLOSE disabled CLOS...

Page 14: ...rliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vorlieg...

Reviews: