![background image](http://html1.mh-extra.com/html/faac/apn/apn_manual_3124755005.webp)
4
ENGLISH
1.3 ANTI-PANIC PARTS
Ball-release for
mobile leaf
Hinge
(not supplied)
Anti-panic hinge
Ball-release for
semi-fixed leaf
On-floor sliding guide
Slide unit
Prepare a
cable grommet
for photocells
wire
Magnetic
contact to stop
the automated
system
Photocells
Fixed leaf or wall
Mobile leaf
Automated system
Automated system
Outside
Outside
Inside
Inside
1.4 INSTALLATION VERIFICATION FOR APN1 - APN2
The APN or APN anti-panic device is used for break-out
through mobile leaves only.
In this configuration, the cross-piece must be installed
on the outside (avoiding direct exposure to rainwater or
atmospheric agents) in order to prevent the break-out of
the sliding leaves interfering with the fixed parts (leaves or
walls) - as shown in figure .