6.7 CONNECTING THE LOCK
If the lock needs to be powered in order to be released,
connect it as indicated in
27
.
If the lock needs to be switched off in order to be
released, connect it as indicated in
28
.
Maximum power consumption: 500 mA 24V
"
.
In advanced programming on the A951:
-
define the operating mode of the lock (parameter
EL
).
-
set the opening delay of the door to allow the
lock to be opened, particularly motorised ones
(parameter
Et
).
-
if necessary, enable the reverse stroke to facilitate
the release of the lock (parameter
rS
).
Access the motor block configuration menu via the
KP EVO in order to set the functions described above.