CYCLE COUNTER
The A951 has two counters:
-
total, non-resettable
-
partial, resettable
This menu allows you to view the cycles performed by
the automation and reset the partial counter.
It is also possible to set a deadline for scheduled
maintenance according to:
-
date (optional)
-
number of cycles (from 1000 to 1000000)
Alert 60 will be displayed as soon as one of the two
settings (date or number of cycles) is reached.
Logging in with the user password only allows data
to be viewed.
DATE / TIME
This menu allows you to set or modify the date, time
and turn European summer time on / off.
To keep the settings even if there is no mains power,
which is necessary for the TIMER to work correctly, a
battery must be installed on the Logic board.
Refer
to § 12.1.
TIMER
This menu includes all the parameters for configuring
the TIMER function.
When the TIMER is enabled, the operating mode of
the door during the programmed time bands is set
automatically.
A maximum of 6 daily time bands can be defined, and
an operating mode, selected from those available,
assigned to each one. Each time band has a start
time and an end time.
The time bands must not overlap.
When the TIMER is enabled, the T icon appears on
the home screen.
To manually change the operating mode set by the
TIMER, it first has to be disabled.
In order for the TIMER to work correctly, a battery must
be installed on the Logic board.
Refer to § 12.1.
In order to quickly program groups of days of the week
with the same time bands, it is possible to simultane-
ously select all the days of the week (MON - SUN) and
all weekdays (MON - FRI). Once the time bands that
have been defined here have been confirmed using the
APPLY option, they will overwrite any time bands that
have already been programmed for individual days.
If it is necessary to program specific days or periods
(e.g. recurring holidays), you may use the JOLLYfunc-
tion.
A maximum of 6 JOLLY time bands can be specified
and an operating mode, selected from those available,
assigned to each one. Each time band has a start
time and an end time.
The time bands must not overlap.
The JOLLY time bands are then assigned to a maximum
of 6 INTERVALS. An interval can be a single day or
a series of days.
If a single day is defined, the start and end date of
the interval must be the same.
The interval must refer to same calendar year (exam-
ple: for the period from 25/12 to 06/01, 2 intervals
must be created, from 25/12 to 31/12 and from
01/01 to 06/01).
PASSWORD
This menu allows passwords to be set or modified.
To access the FUNCTIONS menu you are prompted to
enter a 4-digit password.
The A951 has two passwords available with different
access rights:
13
Access permissions and passwords
TECHNICIAN
PSW
USER
PSW
LANGUAGE
PROGRAMMING
ERRORS
WARNINGS
CYCLES COUNT
(*)
DATE/TIME
TIMER
PASSWORD
(*)
INFO
* with restrictions
The user is only allowed to modify the user password.
Summary of Contents for A951