A951
44
532081 - RevA
Tr
ansla
tion of the original instruc
tions
ENGLISH
0 DISABLED
1 EXTERNAL OPEN
4 INTERNAL OPEN
7 AUTOMATIC OPEN
8 SEMIAUTOM. OPEN
10 KEY
11 PARTIAL OPEN
20 CLOSING SAFETY
21 OPENING SAFETY
30 EMERGENCY OPEN
31 EMER OPEN WITH MEM
34 EMERGENCY CLOSE
35 EMER CLOSE WITH MEM
40 ALWAYS OPEN
41 EXIT ONLY
42 ONLY IN
43 NIGHT
44 MANUAL
45 PARTIAL
46 INTERBLOCK ON
60 TIMER
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
NORMALLY OPENED / NORMALLY CLOSED
TEST
ENABLED / DISABLED
TEST
ENABLED / DISABLED
4 EXTERNAL SELECTOR
POSITION 1 [S1]
POSITION 2 [S2]
0 DISABLED
1 NIGHT
2 OPENED
3 EXIT ONLY
4 MANUAL
2 MOTION
1 OPENING
2 CLOSING
1 SPEED [OS - CS]
2 SLOWDOWN
3 STRENGTH [OF - CF]
4 STRENGTH DURATION [tF]
5 ACCELERATION
6 DECELERATION
1...10
SLOWDOWN SPACE 0°...90°
0...10
0.1...3.0 s
1...10
1...10
SLOWDOWN SPEED 1...3
3 TIMING
1 PAUSE TIME [PA]
2 PAUSE TIME P&G [PG]
3 NIGHT PAUSE TIME [Pn]
4 NIGHT SENSOR DELAY [nD]
0...30 s
0...30 s
0...90 s
0...90 s
4 MOTOR LOCK KIT
1 FUNCTION [El]
DISABLED
NIGHT
EXIT ONLY
NIGHT + MONODIR
ALWAYS
2 LOCK DELAY [Et]
0...60 tenths of a second
3 RELEASE TYPE
WHEN OPENING
CLOSED
5 INSTALLATION
1 ARM TYPE [at]
SKID
ARTICULATE