16
J1
Decoder connector
LD1
(OPEN) Open LED
J2
Low-voltage terminal Block
LD2
(A/C) Partial open/close LED
J3
ADL connector
LD3
(STOP) Stop LED
J4
FAAC lamp output terminal block
LD4
(FTSW) Safety LED
J5
Capacitor connector
LD5
(ADL) Limit switch alarm LED
J6
Electric motor connector
LD6
(FCA) Opening limit switch LED
J7
Transformer primary connector
LD7
(FCC) Closing limit switch LED
J8
Transformer secondary connector
LD8
(S) Power LED
J9
High-voltage terminal block
P1
Opening limit switch programming button
F1
Motor fuse F1, 5 amps,
P2
Closing limit switch programming button
F2
Accessory fuse F2, 1.6 amps
P3
Limit switch/reset programming button
DS1
DIP switch assembly
Figure 12. The layout of the 826 MPS control panel
Operating Logic
Switches S1, S2, and S3 allow you to set the operating
logic of the gate operator (see the section "Operating
Logic" for a complete discussion of the logical
operating modes). Use the table below to set the three
switches.
Logic S1
S2
S3
E1 On On On
E2 On Off Off
A1 Off On On
A2 Off Off Off
S1 Off Off On
S2 On Off On
B On
On
Off
C Off
On
Off
Pause Time
Switches S4 and S5 allow you to set the pause time
between opening and closing for those logical operating
modes that have a pause time defined by the operator.
Use the table below to set your S4 and S5 switches.
Note
: The warning light is on during the last 5
sec of the pause time according to the setting of
switch S6.
Switch
Pause Time, sec
S4
S5
A1, A2, or
S2 Logic:
S1 Logic:
On
On
5
15
Off
On
10
30
On
Off
30
60
Off Off
120
180