10
E1 Logic: How the gate leaf behaves
Leaf
Signal
status
Open or A/C
1
Stop Reversing
Closed
Opens
no effect
no effect
Open
Closes
no effect
no effect
Closing Opens
Stops Opens
Opening Stops
Stops
no
effect
Stopped
Closes
2
no effect
no effect
1
An A/C signal causes the leaf to partially open.
2
The leaf opens if reversing devices are triggered.
E2 Logic: How the gate leaf behaves
Leaf
Signal
status
Open or A/C
1
Stop Reversing
Closed
Opens
no effect
no effect
Open
Closes
no effect
no effect
Closing Opens
Stops
Stops.
Opens
when reversing
device no
longer triggered
Opening Stops
Stops
no
effect
Stopped Closes
2
no effect
no effect
1
An A/C signal causes the leaf to partially open.
2
Leaf opens if reversing devices are triggered.
A1 Logic: How the gate leaf behaves
Leaf
Signal
status
Open or A/C
1
Stop Reversing
Closed Opens,
pauses,
and closes
no effect
no effect
Open Resets
pause
count, pauses,
and closes
Stops
pause
count
Freezes the
pause count until
reversing device
no longer
triggered
Closing Opens
Stops
Opens
Opening no effect
Stops
no effect
Stopped Closes
no effect
no effect
1
An A/C signal causes the leaf to partially open.
A2 Logic: How the gate leaf behaves
Leaf
Signal
status
Open or A/C
1
Stop Reversing
Closed Opens,
pauses,
and closes
no effect
no effect
Open Closes
Stops
pause
count
Closes after 5 sec
when reversing
device no longer
triggered
Closing Opens
Stops
Stops.
Opens
when reversing
device no longer
triggered
Opening no effect
Stops
no effect
Stopped Closes
no effect
no effect
1
An A/C signal causes the leaf to partially open.
S1 Logic: How the gate leaf behaves
Leaf
Signal
status
Open or A/C
1
Stop Reversing
Closed Opens,
pauses,
and closes
no effect
no effect
Open Closes
Stops
pause
count
Closes after 5 sec
when reversing
device no longer
triggered
Closing Opens
Stops
Stops.
Opens
when reversing
device no longer
triggered
Opening Closes
Stops
no
effect
Stopped
Closes
no effect
no effect
1
An A/C signal causes partial opening.
S2 Logic: How the gate leaf behaves
Leaf
Signal
status
Open or A/C
1
Stop Reversing
Closed Opens,
pauses,
and closes
no effect
no effect
Open Closes
Stops
pause
count
Freezes the
pause count until
reversing device
is no longer
triggered
Closing Opens
Stops
Stops.
Opens
when reversing
device no longer
triggered
Opening Closes
Stops
no
effect
Stopped
Closes
no effect
no effect
1
An A/C signal causes partial opening.
B Logic: How the gate leaf behaves
Leaf
Signal
status
Open
A/C
1
Stop Reversing
Closed
Opens
no effect
no effect
no effect
Open
no effect
Closes
no effect
no effect
Closing
no effect
no effect
Stops
Stops
Opening
no effect
no effect
Stops
no effect
Stopped
Opens
Closes
no effect
no effect
1
An A/C signal functions as a close signal in B logic.
C Logic
1
: How the gate leaf behaves
Leaf
Signal
status
Open
A/C
2
Stop Reversing
Closed
Opens
no effect
no effect
no effect
Open
no effect
Closes
no effect
no effect
Closing no
effect Closes Stops Stops
Opening
Opens
no effect
Stops
no effect
Stopped
Opens
Closes
no effect
no effect
1
The leaf moves only while a switch button is pressed.
2
An A/C signal functions as a close signal in C logic.