background image

A

600 mm

400 mm

500 mm

5 mm

=

=

==

B

A

D

C

B

A

B

C

D

ENGLISH

)   Fasten  the  upright  on  the  foundation  plate  using  the  four 

supplied nuts (fig.8) and checking the configuration of the 
barrier as in figure 7.

 

Remember  that  the  hatch  of  the  upright  should  normally 
face the building.

)   Set the operator for manual operation as described in chapter 6.
)   Remove and store the breather screws as shown in Fig.9.
4)   Assemble the beam, using the supplied screws, as shown in 

figures 0 or  (The rubber profile of the beam must face 
in closing direction).

)   Adjust the opening and closing travel limit mechanical stops 

as per fig. 

. and verify beam balancing following the 

instructions in paragraph 4.4.

)   Assemble the foundation plate as in fig.6. ref. 

)   Make a foundation plinth as shown in fig.4 ref.

b

 (referred to 

clayey soil)

)   Wall the foundation plinth as shown in fig.6, ref.

b

, supplying 

one or more sheaths for routing electrical cables. Using a 
spirit level, check if the plate is perfectly level. Wait for the 
cement to set. 

Fig. 6

Fig. 7

  

4.3 MECHANICAL INSTALLATION 

Fig. 9

Fig. 8

Fig. 10

When the barrier 

is open, the spring 

MUST NOT be 

compressed

 

RH

LH

DIMENSION

6

3

0 6

3

0

P

-64

0

A

360

390

B

290

 

320

C

200

 

230

D

94

 

124

4.3.1  BARRIER 6

3

0

Summary of Contents for 630 Series

Page 1: ...SION 8 11 AVAILABLE ACCESSORIES 8 12 DETAILED TECHNICAL SPECIFICATIONS 10 INDEX 2 ELECTRIC PREPARATIONS standard system 4 3 DIMENSIONS 4 3 1 BARRIER 630 4 3 2 BARRIER 630 PLUS 640 4 4 INSTALLING THE A...

Page 2: ...an intrinsic anti crushing safety device consisting of a torque control Nevertheless its tripping threshold must be checked as specified in the Standards indicated at point 10 16 The safety devices EN...

Page 3: ...ual release 27 Spring support position length 460 mm 28 Protective grid for air intakes 29 Plunging piston RH 30 Spring support position length 400 mm 31 Balancing spring support 32 Balancing spring 3...

Page 4: ...ety and an efficiently operating automated system make sure the following conditions are observed When moving the beam must not on any account meet any obstacles or overhead power cables The soil must...

Page 5: ...ust face in closing direction Adjust the opening and closing travel limit mechanical stops as per fig and verify beam balancing following the instructions in paragraph 4 4 Assemble the foundation plat...

Page 6: ...ise To reduce torque turn the screws anti clockwise 5 3 ADJUSTING THE TRAVEL LIMIT SLOW DOWN For beams with a length of over 4 m we advise you not to set too brief a slow down Adjust the cams of the t...

Page 7: ...rrect operation of the barrier pointing out the potential danger zones 6 MANUAL MODE OPERATION If the barrier has to be moved manually due to a power cut or fault of the automated system operate the r...

Page 8: ...against the opening travel limit mechanical stop Remove the pinion pocket and re install it to set the barrier at opening as in figure 19 Fit the feed pipes as shown in Fig 19 according to the configu...

Page 9: ...ossible END FOOT The end foot allows the beam to rest when closed and thus prevents the profile bending downward IMPORTANT If a foot is installed the balancing spring must be adapted if possible FORK...

Reviews: