background image

413

ENGLISH

Guide for the installer

Page

Thank you for choosing our product. FAAC is sure that it will give you 

all the performances you are looking for. All our products are the 

result of a long experience in the field of the automated systems.

  In the middle of the handbook you will find a detachable 

brochure with the images for the installation.

The 

413

 automated system for swing gates is an electro-mecha-

nical non-reversing operator that transmits motion to the leaf via 

a worm screw system.

The operator is available in several versions. The “LS” versions are 

equipped with opening and closing limit switches. Every version is 

supplied with opening and closing mechanical travel stops.

The non-reversing system ensures the leaf is mechanically locked 

when the motor is not operating. A convenient and safe release 

system with customised key makes it possible to manually move the 

leaf in the event of a malfunction or of a power failure.

IMPORTANT NOTES FOR INSTALLER

Before starting the installation of the operator read this manual 

completely.

Keep this manual for future reference.

Smooth operation and specifications are obtained only declared 

following the directions given in this handbook and with acces-

sories and safety devices FAAC.

The lack of a mechanical clutch device requires to ensure an 

adequate level of security automation, the use of a central control 

device with an electronically controlled clutch.

The  automation  was  designed  and  built  to  control  vehicular 

access. Avoid any other use.

The operator can not be used to handle emergency exit routes 

or gates installed on emergency (escape routes).

If there is built-in anti motorize from a door to the walkway is requi-

red to add a safety switch on the door, connected on the entry 

of STOP, to inhibit the operation of automation with door open.

Everything  that  is  not  expressly  stated  in  this  manual  is  not  al-

lowed.

1. DESCRIPTION (Fig. 1)

Pos.

Description

a

Operator

b

Release device

c

Limit switch cover

d

Closing limit switch 

a

e

Opening limit switch 

a

f

Front bracket

g

Rear fitting

h

Rear fitting pin

i

Rear bracket

j

Terminal board cover

a

 

Only where “LS”

2. TECHNICAL SPECIFICATIONS

Technical specifica-

tions

Model

413

413

 LS

413

 

24V

413

 LS

 

24V

413

 

115V

413

 LS

 

115V

Power supply

230 V~

24 V

115 V~

Power (W)

250

70

260

Current (A)

1.1

3

2.2

Thermal protection 

(°C)

140

/

140

Capacitor (µF)

6.3

/

20

Thrust (daN)

200

250

200

Rated thrust (daN)

140

170

140

Travel (mm)

300 

a

Speed (cm/sec)

1.6

1.85

Noisiness (dBA)

<70

Leaf max. (m)

2.5 

b

Type and use fre-

quency at 20° C

S3 

30%

S3 

35%

100%

S3 

30%

S3 

35%

Technical specifica-

tions

Model

413

413

 LS

413

 

24V

413

 LS

 

24V

413

 

115V

413

 LS

 

115V

Approximate min. 

cycle/hour at 20° C

~ 30

~ 100

~ 30

Operating ambient 

temperature  (°C)

-20  +55

Operator weight (Kg)

6.5

Operator dimensions 

(mm)

See Fig. 2

Protection class

IP54

a

  If no closing and opening mechanical travel stops are used, the 

operator travel is 350 mm.

b

  With  leaves  exceeding  1.8  m  the  fitting  of  an  electric  lock  is 

required to ensure the leaf locking.

2.1. Versions

Model

Version

413

230V~  operator  with  opening/closing  mechanical 

travel stops

413 LS

230V~ operator with opening/closing mechanical tra-

vel stops and opening/closing limit switches

413 24V

24V  operator with opening/closing mechanical travel 

stops

413 LS 24V 24V  operator with opening/closing mechanical travel 

stops and opening/closing limit switches

413 115V

115V~  operator  with  opening/closing  mechanical 

travel stops

413 LS 115V 115V~ operator with opening/closing mechanical tra-

vel stops and opening/closing limit switches

  For CSA-UL approved operators, control unit  455 MPS UL 115 

must be used in order to maintain the approval.

3. INSTALLATION

3.1. Electrical set-up (standard system Fig. 3)

Pos.

Description

Cables section

a

Operators 

a

4x1.5mm

2

 (2x1.5mm

2

)

b

Control unit 

3x1.5mm

 

(power supply)

c

TX photocells 

2x0.5mm

2

d

RX photocells 

4x0.5mm

2

e

Key-operated selector switch 

b

2x0.5mm

(3x0.5mm

2

)

f

Flashing lamp

2x1.5mm

2

g

Receiver

3x0.5mm

2

h

Mechanical stops on the ground

a

 The value in parentheses refers to the motors at 24 V

b

  The value in parentheses refers to the switch with two contacts

  Use suitable tubes and/or hoses to lay electric cables

  To avoid any kind of interference always separate low-vol-

tage accessories and control cables from 230/115 V~ power 

supply cables using separate sheaths.

3.2. Preliminary checks

To ensure a correct operation of the automated system, make sure 

the following requirements are observed as for the gate structure 

(existing or to be realised):

the mechanical parts must conform to the provisions of Standards 

EN 12604 and EN 12605.

leaf length in compliance with the operator specifications.

sturdy and stiff structure of the leaves, suitable for automation

regular and uniform movement of the leaves, without any friction 

and dragging during their entire opening.

stiff hinges in good conditions.

presence  of  both  opening  and  closing  mechanical  limit  stops 

(they are not necessary if opening and closing mechanical travel 

stops are used).

presence  of  an  efficient  earthing  for  electrical  connection  of 

Summary of Contents for 413 Series

Page 1: ...413...

Page 2: ...19 20 21 22 23 24 25 26 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 of a torque control Nevertheless its tripping threshold must be checked as specified in the Standards indicated at point 10 The safety d...

Page 3: ...Compatibility directive and also declares that it is prohibited to put into service the machinery until the machine in which it will be integrated or of which it will become a component has been ident...

Page 4: ...300 a Speed cm sec 1 6 1 85 Noisiness dBA 70 Leaf max m 2 5 b Type and use fre quency at 20 C S3 30 S3 35 100 S3 30 S3 35 Technical specifica tions Model 413 413 LS 413 24V 413 LS 24V 413 115V 413 LS...

Page 5: ...power to the operator to position the fitting The operator can be moved by hand only if it is installed on the gate and in released position see paragraph 5 Assemble the front bracket as shown in Fig...

Page 6: ...ence to the indications in Fig 3 set the ducts and carry out the electrical connections of the control board and of the chosen accessories Always separate power cables from control and safety cables p...

Page 7: ...413 Immagini Images Images Im genes Bilder Afbeeldingen Pag Fig 1 Fig 2...

Page 8: ...413 Immagini Images Images Im genes Bilder Afbeeldingen Pag Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10...

Page 9: ...413 Guida per l utente User s guide Instructions pour l utilisateur Gu a para el usuario Anweisungen f r den Benutzer Gebruikersgids...

Page 10: ...rol or by any other pulse generator it activates the electro mechanical operator to rotate the leaves until they reach the opening position to provide access For detailed operation of the automated sy...

Page 11: ...ng 1 Velligheldsvoorziening 1 Dispositivo di sicurezza 2 Safety device 2 dispositif de s curit 2 Dispositivo de seguridad 2 Scherhelt svorrichtung 1 Velligheldsvoorziening 2 Coppia di fotocellule 1 Pa...

Page 12: ...chnicien T cnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 4 Tecnico Technicia Technicien T cnico Techniker Technicus Cliente Customer Client Cliente Kunde Klant 5 Tecnico Techni...

Page 13: ...413 Note Notes Note Notas Anmerkung Opmerkingen Page 10...

Page 14: ...413 Note Notes Note Notas Anmerkung Opmerkingen Page 11...

Page 15: ...n vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vor...

Page 16: ...413 Immagini Images Images Im genes Bilder Afbeeldingen Pag Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18...

Page 17: ...413 Immagini Images Images Im genes Bilder Afbeeldingen Pag Fig 19 Fig 20 Fig 21 Fig 22 Fig 23 Fig 24 Fig 25 Fig 26...

Page 18: ...413 Note Notes Note Notas Anmerkung Opmerkingen Page 30...

Page 19: ...413 Note Notes Note Notas Anmerkung Opmerkingen Page 31...

Page 20: ...413 Note Notes Note Notas Anmerkung Opmerkingen Page 32...

Page 21: ...n vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vor...

Reviews: