4. PROGRAMMING
OPERATING LOGIC
DS 1: SW 1 - SW 2 - SW 3
LOGIC
SW
1
SW
2
SW
3
PAUSE
TIME
DESCRIPTION
E (default)
Semiautomatic
OFF OFF OFF
NO
One command opens, the next one closes. A command du-
ring opening stops the gate
A
Automatic
ON
ON
ON
0 - 4
min
One command opens, waits for the pause time an then closes
automatically
S
Security
OFF OFF ON
0-4
min
One command opens, waits for the pause time and then clo-
ses automatically. If the closing safety is activated or another
command is given during the pause time it closes
EP
Semiautomatic
step by step
OFF ON OFF
NO
One command opens, the next one closes. During the move-
ment a command stops the gate
AP
Automatic
step by step
OFF ON
ON
0-4
min
One command opens, waits for the pause time and then clo-
ses automatically. A command during the pause time holds
the gate open
SP
Security
step by step
ON OFF OFF
0-4
min
One command opens, waits for the pause time and then
closes automatically. If the closing safety is activated during
pause time the gate closes in 5 s. A command during pause
time holds open the gate
B
Manned Pulsed
ON OFF ON
NO
An open A command opens the gate, an open B command
closes the gate
C
Manned Constant
ON
ON OFF
NO
Holding open A active opens the gate, holding Open B active
closes the gate
For more details on the operating logics please refer to Chapter 12 - Function Logics