Note: If after a few seconds, you do not see the additional HDD in the disk summary, the drive might
not be seated properly. If this occurs, remove and reinsert the drive.
7.
Add the replacement drive (HD2 in the example) to the array.
tmsh modify sys raid array MD1 add HD2
The status of the replacement drive should change to replicating, and the STAT LED should change to
solid green. The replication process typically takes between 15 and 45 minutes.
8.
Attach the front bezel to the unit by grasping the bezel using the indentations located on either side.
Note: Failure to use the indentations could result in pinched fingers.